STUD
FINISHING RING &
SCREW LOCATIONS (4)
2 ON BOTTOM
EACH SIDE &
PLUG, 1 ON
1/2-14 NPT
(MOUNTEDFROM INSIDE
HOUSING)
THERMAL PROTECTOR
FINE ADJUSTMENT
SLOT
CROSS BRACKETS
L-BRACKETS (4)
CROSS BRACKET TAB
WALL BOARD
THICKNESS
(NAILS SUPPLIED
BY CUSTOMER)
+ 1/8 INCH
FLAG
TEMPLATE
HOLE
EACH SIDE &
1/2-14 NPT
2 ON BOTTOM
PLUG, 1 ON
FASTENER
THERMAL
MOUNTING
SCREWS &
SCREW HOLES
PROTECTOR
(MOUNTED FROM
INSIDE HOUSING)
"L" BRACKETS
MASONRY BRACKET
LOWER
1/2-14 NPT PLUG
1 ON EACH SIDE &
2 ON BOTTOM
WASHER,
BRACKET
SCREW,
BRACKET
HOLES
MORTAR
FRONT OF
HOUSING
EXTENDS PAST
BRICK 1/8 INCH
Install two screws through washers and lower masonry
brackets and into tapped housing holes on bottom of
fixture.
Remove the 1/2" NPT plugs from the side/bottom of the
housing and pull supply wires through holes and into
housing.
Leaving 1/8" of housing extending past front of wall,
press fixture and lower masonry brackets into a layer of
mortar so that the mortar penetrates through the holes
of the masonry brackets.
After laying another course of blocks, install the two
upper masonry brackets onto the housing as above.
(USE ACCESSORY KET #MAKM)
INSTALLATION FOR MASONRY WALL
Using the template supplied, cut a level hole through the
existing wall between existing studs. Failure to level
the hole will cause the fixture to have a tilted appearance.
Push the four mounting screws through the housing holes
and into rear channels. (NOTE: A thin membrane covers
the housing holes and may require forcing the screws
through to penetrate the membrane.
Place flags flat on rear of housing and thread screws
into flags until the screws are completely through the flags.
Install four "L" brackets on housing with four screws.
Remove the 1/2" NPT plugs from the side/bottom of the
housing and pull the supply wires through into the housing.
Push housing into the hole in the wall and tighten four
mounting screws until the flag fasteners have drawn tightly
up against the rear surface of the wall.
Install thermal protector.
(USE ACCESSORY KET #MAKEC)
INSTALLATION FOR EXISTING STUD WALL
Using the template supplied, cut a level hole through
the wall board to fit around the fixture housing. Failure
to level the hole will cause the fixture to have a tilted
appearance.
Mount "L" brackets onto housing 4 places with screw
positioned in center of slot, and insert cross brackets
through the "L" brackets on top and bottom of housing.
Position fixture so that the housing extends past the
studs the thickness of the wallboard plus 1/8 inch.
Level fixture and hammer tabs on cross brackets into
studs, then nail brackets securely to studs.
Fine adjust fixture position and tighten all loose screws.
Remove the 1/2" NPT plugs from the side/bottom of the
housing and pull supply wires through holes and into
housing.
Install wall board.
Install thermal protector.
(USE ACCESSORY KET #MAKNS)
INSTALLATION FOR NEW STUD WALL
page 2 of 3
32000896, revision
E