background image

Metal Compensation 

If high metal content is present in, or near, the hearing loop, the sound heard by the loop 
listening device may be ‘woolly’ or ‘dull’. To rectify, select the 

Metal Comp

 display and press 

the 

Down

 

and 

Up

 

4

 control buttons until a natural balance is achieved.

VU

Down

Up

min

max

Phantom Phase

Limit Peak

1 2

Metal Comp

Loop 1 Drive

Digital

Fault

HOT!

7 of 16

SigNET PRO Range Instructions

Approved Document No. DAU0000105 Rev 2

Digital (Model Dependent) 

This menu display can be used to adjust the sensitivity of the digital input signal. 

Select the 

Digital

 display and press the 

Up

 

4

and 

Down

 

control buttons to adjust the 

digital input level.

VU

Digital

Outreach

Metal Comp

Down

Up

min

max

Phantom Phase

Limit Peak

Fault 1 2

HOT!

Outreach 

This menu display can be used to adjust the sensitivity of the outreach plate input signal. 

Select the 

Outreach

 display and press the 

Up

 

4

and 

Down

 

control buttons to adjust the 

outreach input level.

VU

Outreach

Phantom

Digital

Down

Up

min

max

Phantom Phase

Limit Peak

Fault 1 2

HOT!

Phantom 

This menu display is used to apply optional 12V phantom power for use with electret 
microphones. By default, the amplifier will have phantom power turned off. 
 
Select the 

Phantom

 display and press the 

On

 

4

 and 

Off

 

 control buttons to toggle 

microphone phantom power on and off, as shown below.

VU

Phantom

Microphone

Outreach

Off

On

min

max

Phantom Phase

Limit Peak

Fault 1 2

HOT!

VU

Phantom

Microphone

Outreach

Off

On

min

max

Phantom Phase

Limit Peak

Fault 1 2

HOT!

The SigNET PRO Range amplifiers are fully 
compatible with the outreach plate audio 
input extension system. This system allows 
the connection of multiple microphones, 
or line level inputs via a range of specially 
designed wall, ceiling or desk-mountable 
single gang plates. 
 
Up to ten outreach plates (any mix) can be 
daisychained to the amplifier’s ‘outreach’ 
connector with cable lengths up to 100m 
(total network length) easily achievable 
using standard two pair audio cable such as 
Belden 8723 - see typical wiring diagrams. 
 
Please contact SigNET technical 
department for more information.

PRO RANGE

4-WAY OUTREACH

CONNECTOR

A +

A -

V+

0V

OUTREACH PLATE

AUDIO INPUT

A OUT +

A OUT -

A IN +

A IN -

V+

GND

GREEN (A+)

WHITE (A-)

RED (V+)

BLACK (GND)

OUTREACH PLATE

AUDIO INPUT

A OUT +

A OUT -

A IN +

A IN -

V+

GND

GREEN (A+)

WHITE (A-)

RED (V+)

BLACK (GND)

A
B

D

C

E

F

A
B

D

C

E

F

MULTIPLE OUTREACH PLATE WIRING CONNECTIONS

TO NEXT

OUTREACH

PLATE

PRO RANGE

4-WAY OUTREACH

CONNECTOR

A

B

C

D

E

F

SINGLE OUTREACH PLATE

WIRING CONNECTIONS

e.g. APL / APM Outreach Plate

A OUT-

A OUT+

V+

GND

A+

A-

V+

0V

A

F

E

B
C
D

RED (V+)

GREEN (A OUT+)

WHITE (A OUT-)

BLACK (GND)

NOT USED

NOT USED

GREEN (A+)

BLACK (GND)

RED (V+)

GREEN (A+)

WHITE (A-)

RED (V+)

BLACK (GND)

WHITE (A-)

A IN+

A IN-

This output may be used to connect multiple SigNET PRO 
Range hearing loop amplifiers to cover larger areas. 
 
The audio line output should be wired with Ve from 
A+, signal -Ve from A- and screen from 0V, as shown right. 

 
The amplifier mixes and amplifies the microphone, line in, 
outreach input signals, optical (model dependent) and sends 
this signal through the Line Out connector before feeding 
them through the AGC circuitry.

PRO RANGE

3-WAY LINE OUT

 CONNECTOR

0V

A-

A+

BLACK (GND)

GREEN (A+)

WHITE (A-)

Outreach Connector

Line Out Connector

AMPLIFIER CONNECTIONS

10 of 16

SigNET PRO Range Instructions

Approved Document No. DAU0000105 Rev 2

Summary of Contents for Pro Series

Page 1: ...tal receiver Up to 24 bit 96kHz sampling OUTPUTS Loop 1 Loop 2 model dependent Type True current mode Loop output voltage 14V Single Loop drive current 1 ohm 4 75A PRO5 SD PRO5 SW 7 5A PRO7 SD PRO7 SW 11A PRO11 SD PRO11 SW Dual Loop drive current 1 ohm 2 x 3 25A PRO5 DD PRO5 DW 2 x 5A PRO7 DD PRO7 DW 2 x 7 5A PRO11 DD PRO11 DW Line Out 775mV output Fault Relay Single pole double throw SPDT NC Comm...

Page 2: ...rom being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 10 Only use attachments accessories specified by the manufacturer 11 Unplug this apparatus during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any ...

Page 3: ...rt numbers listed above 1 x Accessory pack containing instructions this document two ferrite beads for the loop cables pluggable connectors for the outreach line out relay line in microphone terminals hearing loop fitted sticker 230V 50Hz Power max 200W Fuse T 5A H 250V No user controls or user serviceable parts inside LOOP 2 OPTICAL OPTIONAL RELAY NO COM NC LINE OUT 0V A A OUTREACH 0V A A V 1 2 3...

Page 4: ...2 for alternative wall mount model connections 1 IMPORTANT DO NOT power up the system before completing Step 3 below The amplifier MUST NOT be operated without a loop connected to it Install Loop 1 Cable and Loop 2 Cable model dependent See Phased array hearing loop systems page 9 for example dual loop layouts BEFORE connecting the loops to the amplifier use a multimeter to check the loops are not...

Page 5: ... metal base securely onto a vertical wall 2m mounting height Assess the condition and construction of the wall and use suitable screw fixings for the in service weight of the product The mounting holes are suitable for use with ø4 5mm countersunk screws Any dust or swarf created during the mounting process must be kept out of the enclosure and due care must be taken not to damage any wiring or com...

Page 6: ... 2 CONNECTIONS NOT SHOWN Ensure the ferrite bead supplied is fitted at the terminal block A LOOP 1 A Loop Connectors Wall Mount Model Only Microphone Connector Wall Mount Model Only Line In Connector Wall Mount Model Only Menu Displays Use the Left and4 Right buttons to scroll through the amplifier s menu displays listed right 1 Line Input 2 Microphone 3 Phantom 4 Outreach 5 Digital model dependen...

Page 7: ... the outreach plate audio input extension system This system allows the connection of multiple microphones or line level inputs via a range of specially designed wall ceiling or desk mountable single gang plates Up to ten outreach plates any mix can be daisychained to the amplifier s outreach connector with cable lengths up to 100m total network length easily achievable using standard two pair aud...

Page 8: ...ation Note 3 Metal compensation tests must be carried out to comply with the requirements of BS EN 60118 4 Loop Drive 1 Loop Drive 2 Drive Model Dependent These menu displays are used to adjust the strength of the magnetic field generated by induction loops 1 2 by increasing the output current being driven into the loops To comply with BS EN 60118 4 Output field strength should be set up using a F...

Reviews: