background image

3 of 16

SigNET PRO Range Instructions

Approved Document No. DAU0000105 Rev 2

Part No.

Description

SINGLE LOOP AMPLIFIERS

PRO5/SD

Free-Standing, Hearing Loop Amplifier with Graphic Display, 
Single Loop 4.75 Amp (230V Mains Lead Connection)

PRO5/SW

Wall-Mount, Hearing Loop Amplifier with Graphic Display, 
Single Loop 4.75 Amp (230V Fixed Mains Connection)

PRO7/SD

Free-Standing, Hearing Loop Amplifier with Graphic Display, 
Single Loop 7.5 Amp (230V Mains Lead Connection)

PRO7/SW

Wall-Mount, Hearing Loop Amplifier with Graphic Display, 
Single Loop 7.5 Amp (230V Fixed Mains Connection)

PRO11/SD

Free-Standing, Hearing Loop Amplifier with Graphic Display, 
Single Loop 11 Amp (230V Mains Lead Connection)

PRO11/SW

Wall-Mount, Hearing Loop Amplifier with Graphic Display, 
Single Loop 11 Amp (230V Fixed Mains Connection)

DUAL LOOP AMPLIFIERS

PRO5/DD

200m

2

 Free-Standing, Phase-Shifted, Hearing Loop Amplifier with Graphic 

Display and TOSLINK, Dual Loop 2 x 3.25 Amp (230V Mains Lead Connection)

PRO5/DW

200m

2

 Wall-Mount, Phase-Shifted, Hearing Loop Amplifier with Graphic 

Display and TOSLINK, Dual Loop 2 x 3.25 Amp (230V Fixed Mains Connection)

PRO7/DD

500m

2

 Free-Standing, Phase-Shifted, Hearing Loop Amplifier with Graphic 

Display and TOSLINK, Dual Loop 2 x 5 Amp (230V Mains Lead Connection)

PRO7/DW

500m

2

 Wall-Mount, Phase-Shifted, Hearing Loop Amplifier with Graphic 

Display and TOSLINK, Dual Loop 2 x 5 Amp (230V Fixed Mains Connection)

PRO11/DD

1000m

2

 Free-Standing, Phase-Shifted, Hearing Loop Amplifier with Graphic 

Display and TOSLINK, Dual Loop 2 x 7.5 Amp (230V Mains Lead Connection)

PRO11/DW

1000m

2

 Wall-Mount, Phase-Shifted, Hearing Loop Amplifier with Graphic 

Display and TOSLINK, Dual Loop 2 x 7.5 Amp (230V Fixed Mains Connection)

SIGNET PRO RANGE PART NUMBERS

Free-Standing Model Kit Contents 

 

1  x  Hearing loop amplifier (part numbers listed above) 

1  x  Fused mains lead 

1  x  Accessory pack containing instructions (this document), four self-adhesive rubber feet, 

pluggable connectors (for the outreach, line out & relay terminals), ‘hearing loop fitted’
sticker. 

 

Wall-Mount Model Kit Contents 

 

1  x  Hearing loop amplifier (part numbers listed above) 

1  x  Accessory pack containing instructions (this document), two ferrite beads (for the loop 

cables), pluggable connectors (for the outreach, line out, relay, line in & microphone 
terminals), ‘hearing loop fitted’ sticker.

230

 

V      50

 

Hz

Power (max.) 200W

Fuse T 5A H 250V

No user controls or user
serviceable parts inside 

LOOP 2

OPTICAL

OPTIONAL

RELAY

NO

COM

NC

LINE OUT

0V A- A+

OUTREACH

0V

A- A+

V+

1

2 3

1 GND  

2    +

3    –

MICROPHONE

(PHANTOM 12V)

LINE IN

LOOP 1

4

Connect Power (model dependent) 

Connect the mains lead (supplied) to a 230Va.c. wall socket and the 
amplifier‘s 230Va.c. connector. 
Switch on power and the amplifier will be unlocked and show the 

Line Input

 menu display.

5

Set up the Amplifier’s Inputs 

Note:

 By default, all inputs to the amplifier are factory set to their lowest settings. 

Activate all relevant audio input source(s), i.e. mic., line in, outreach, optical (model dependent). 

Select the relevant display, e.g. 

Line Input

, and use the 

Up

 

4

 control button to adjust 

the signal level until the 

Limit

 indicator flashes occasionally, as shown below.

6

Set up the Loop Drives 

Select the

 Loop Drive 1 

display and use the 

Up

 

4

 control button to increase the loop 

field strength, as shown below. For dual loop amplifiers, select the 

Loop Drive 2

 display 

and repeat this procedure.

7

Metal Compensation 

 
For applications with high metal content in, or near, the hearing loop, select the 
amplifier’s 

Metal Comp

 display. Increase the metal compensation by small increments 

using the 

Up

 

4

 control button until a natural balance is achieved. 

 

Note:

 If high metal content is present, the amplifier’s area of coverage will be reduced, 

and further reduced, as the 

Metal Compensation

 level is increased.

Repeat this procedure by selecting the relevant display and adjusting the signal level. If 
a microphone is used, enable 

Phantom

 on the display. Also, enable 

Phase Shift

 (model 

dependent) on the display for phased array systems.

VU

Line Input

Key Lock

Microphone

Down

Up

min

max

Phantom Phase

Limit Peak

Fault 1 2

HOT!

CAUTION:

 Ensure the 

Peak

 indicator is not permeantly lit. This may cause the 

amplifier to shutdown to protect it from overheating.

VU

Loop 1 Drive

Metal Comp

Loop 2 Drive

Down

Up

min

max

Phantom Phase

Limit

Fault 1 2

HOT!

Peak

14 of 16

SigNET PRO Range Instructions

Approved Document No. DAU0000105 Rev 2

Summary of Contents for Pro Series

Page 1: ...tal receiver Up to 24 bit 96kHz sampling OUTPUTS Loop 1 Loop 2 model dependent Type True current mode Loop output voltage 14V Single Loop drive current 1 ohm 4 75A PRO5 SD PRO5 SW 7 5A PRO7 SD PRO7 SW 11A PRO11 SD PRO11 SW Dual Loop drive current 1 ohm 2 x 3 25A PRO5 DD PRO5 DW 2 x 5A PRO7 DD PRO7 DW 2 x 7 5A PRO11 DD PRO11 DW Line Out 775mV output Fault Relay Single pole double throw SPDT NC Comm...

Page 2: ...rom being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 10 Only use attachments accessories specified by the manufacturer 11 Unplug this apparatus during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any ...

Page 3: ...rt numbers listed above 1 x Accessory pack containing instructions this document two ferrite beads for the loop cables pluggable connectors for the outreach line out relay line in microphone terminals hearing loop fitted sticker 230V 50Hz Power max 200W Fuse T 5A H 250V No user controls or user serviceable parts inside LOOP 2 OPTICAL OPTIONAL RELAY NO COM NC LINE OUT 0V A A OUTREACH 0V A A V 1 2 3...

Page 4: ...2 for alternative wall mount model connections 1 IMPORTANT DO NOT power up the system before completing Step 3 below The amplifier MUST NOT be operated without a loop connected to it Install Loop 1 Cable and Loop 2 Cable model dependent See Phased array hearing loop systems page 9 for example dual loop layouts BEFORE connecting the loops to the amplifier use a multimeter to check the loops are not...

Page 5: ... metal base securely onto a vertical wall 2m mounting height Assess the condition and construction of the wall and use suitable screw fixings for the in service weight of the product The mounting holes are suitable for use with ø4 5mm countersunk screws Any dust or swarf created during the mounting process must be kept out of the enclosure and due care must be taken not to damage any wiring or com...

Page 6: ... 2 CONNECTIONS NOT SHOWN Ensure the ferrite bead supplied is fitted at the terminal block A LOOP 1 A Loop Connectors Wall Mount Model Only Microphone Connector Wall Mount Model Only Line In Connector Wall Mount Model Only Menu Displays Use the Left and4 Right buttons to scroll through the amplifier s menu displays listed right 1 Line Input 2 Microphone 3 Phantom 4 Outreach 5 Digital model dependen...

Page 7: ... the outreach plate audio input extension system This system allows the connection of multiple microphones or line level inputs via a range of specially designed wall ceiling or desk mountable single gang plates Up to ten outreach plates any mix can be daisychained to the amplifier s outreach connector with cable lengths up to 100m total network length easily achievable using standard two pair aud...

Page 8: ...ation Note 3 Metal compensation tests must be carried out to comply with the requirements of BS EN 60118 4 Loop Drive 1 Loop Drive 2 Drive Model Dependent These menu displays are used to adjust the strength of the magnetic field generated by induction loops 1 2 by increasing the output current being driven into the loops To comply with BS EN 60118 4 Output field strength should be set up using a F...