background image

SIGNET PRO RANGE HEARING LOOP AMPLIFIERS 

Part Numbers: 

PRO5/SD, PRO5/SW, PRO7/SD, PRO7/SW, PRO11/SD, PRO11/SW, 
PRO5/DD, PRO5/DW, PRO7/DD, PRO7/DW, PRO11/DD, PRO11/DW

The SigNET PRO Range comprises of constant current, single and dual induction hearing loop 
amplifiers, each with a graphical display. The dual loop amplifiers have a built-in phase shifter, 
designed for ‘phased array’ induction loop systems. They may be free-standing, or wall-
mounted and are designed to cover areas up to 200m

2

, 500m

2

 or 1000m

2

 (model dependent). 

 
 

Safety Guidelines and Important Notes .............................................................................. 2 

SigNET PRO Range Part Numbers and Kit Contents ........................................................... 3 

Overview of the SigNET PRO Range Hearing Loop Amplifier ........................................ 4-5 

Amplifier Operation and Menu Displays ......................................................................... 5-8 

Phased Array Hearing Loop Systems .................................................................................. 9 

Amplifier Connections ................................................................................................... 10-11 

Mounting the Amplifiers .............................................................................................. 11-12 

Connecting, Setting Up and Testing the System ......................................................... 13-15 

SigNET PRO Range Technical Specification ....................................................................... 16

INSTALLATION & OPERATOR INSTRUCTIONS

1 of 16

SigNET PRO 

Wall-Mount 

Model

SigNET PRO Range Instructions

Approved Document No. DAU0000105 Rev 2

SigNET PRO 

Free-Standing 

Model

THIS EQUIPMENT MUST BE INSTALLED AND MAINTAINED BY A SUITABLY SKILLED 
AND TECHNICALLY COMPETENT PERSON.

16 of 16

SigNET PRO Range Instructions

Approved Document No. DAU0000105 Rev 2

E&OE. No responsibility can be accepted by the manufacturer or distributors of these power supplies for any misinterpretation of this instruction, or for the 
compliance of the system as a whole. The manufacturers policy is one of continuous improvement and we reserve the right to make changes to product 
specifications at our discretion and without prior notice.

SIGNET PRO RANGE TECHNICAL SPECIFICATION

POWER

Supply Voltage:

230V 

 50Hz (Free-standing model is supplied with IEC 320 fused mains lead; Wall-mount 

model is permanently connected to mains)

Power Consumption:

100W / 200W / 400W (model dependent)

INPUTS

Line In:

Input impedance: 1k + or – input to ground. 
Sensitivity: -20dBU typical.

Microphone:

Input impedance: 1k + or – input to ground. 
Sensitivity: -42dBU typical. 
Phantom power for electret microphones: 12V selectable (on/off).

Outreach:

Input impedance: >10k. 
Sensitivity: 0dBU typical. 
Outreach power: 24V d.c. nom. is available via the amplifier’s outreach connector (100mA max.)

Optical (model dependent)

:

TOSLink digital receiver. Up to 24 bit, 96kHz sampling.

OUTPUTS

Loop 1 & 
Loop 2 (model dependent):

Type: True current mode. Loop output voltage: 14V. 
Single Loop drive current @ 1 ohm: 4.75A (PRO5/SD, PRO5/SW); 7.5A (PRO7/SD, PRO7/SW); 11A 
(PRO11/SD, PRO11/SW). 
Dual Loop drive current @ 1 ohm: 2 x 3.25A (PRO5/DD, PRO5/DW); 2 x 5A (PRO7/DD, PRO7/DW); 
2 x 7.5A (PRO11/DD, PRO11/DW).

Line Out:

775mV output

Fault Relay:

Single pole double throw (SPDT): NC, Common, NO.

Phase Shift (model dependent):

2 x 90

0

 phase shifted. Selectable (on/off).

Metal Compensation:

Up to 10dB / octave design counteracts frequency dependent absorption by metal in the 
installation over a bandwidth of approximately 5kHz.

COVERAGE

Maximum Coverage Area:

 

200m

2

, i.e. rooms up to approx. 14m x 14m (PRO5/DD, PRO5/DW). 

500m

2

,

i.e. rooms up to approx. 22m x 22m (PRO7/DD, PRO7/DW). 

1000m

2

, i.e. rooms up to approx. 31m x 31m

 

(PRO11/DD, PRO11/DW). 

Loop impedance:

 0.5 to 2 ohm.

PERFORMANCE

Frequency Response (-3dB): 

100Hz to 5kHz; 

Distortion: 

Less than 1 % typical; 

Signal to Noise Ratio: 

Better than –65dB any 

input; 

AGC Range (3dB change in output voltage current): 

10dB. AGC ratio: 20:1.

SUPPLEMENTARY

Sensitivity Level Controls 
(lockable via display):

Line Input, Microphone, Phantom, Outreach, Optical (model dependent), Metal Comp, Loop 
Drive 1, Loop Drive 2 (model dependent), Phase Shift (model dependent), Brightness.

Display & Controls:

256 x 64 pixel OLED display with 4 membrane control buttons.

Connectors:

• Microphone (3-pin XLR Type - Free-standing model; 3-way pluggable connector - Wall-mount model). 
• Line In (3-pin XLR Type - Free-standing model; 3-way connector - Wall-mount model). 
• Loop (2 or 4 way binding post - Free-standing model; 2 or 4-way connector - Wall-mount model). 
• Outreach (4-way pluggable connector). 
• Line Out (3-way pluggable connector). 
• Fault Relay (3-way pluggable connector). 
• Optical (model dependent). 
• 230Va.c. connector (Mains lead supplied for Free-standing model; Fixed mains connection 

for Wall-mount model).

Overall Dims. (H x W x D):

Free-standing models: 67mm (H) x 218mm (W) x 280mm (D) 
Wall-mount models: 298mm (H) x 308mm (W) x 74mm (D)

Weight:

Free-standing models: 2.38kg; Wall-mount models: 3.35kg

Panel Construction:

Mild steel zintec, 1mm thick, black powder coated

IP Rating (EN 60529):

IP40

Operating Temperature:

0

0

C to 40

0

C

Maximum Humidity:

95% non-condensing

Manufacturer: SigNET AC Ltd, 6 Tower Road, Washington, Tyne & Wear NE37 2SH. 

www.signet-ac.co.uk

.

Wall-Mount Model Numbers 

PRO5/SW, PRO7/SW, PRO11/SW, PRO5/DW, PRO7/DW, PRO11/DW

.

 

Free-Standing Model Numbers 

PRO5/SD, PRO7/SD, PRO11/SD, PRO5/DD, PRO7/DD, PRO11/DD

Summary of Contents for Pro Series

Page 1: ...tal receiver Up to 24 bit 96kHz sampling OUTPUTS Loop 1 Loop 2 model dependent Type True current mode Loop output voltage 14V Single Loop drive current 1 ohm 4 75A PRO5 SD PRO5 SW 7 5A PRO7 SD PRO7 SW 11A PRO11 SD PRO11 SW Dual Loop drive current 1 ohm 2 x 3 25A PRO5 DD PRO5 DW 2 x 5A PRO7 DD PRO7 DW 2 x 7 5A PRO11 DD PRO11 DW Line Out 775mV output Fault Relay Single pole double throw SPDT NC Comm...

Page 2: ...rom being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 10 Only use attachments accessories specified by the manufacturer 11 Unplug this apparatus during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any ...

Page 3: ...rt numbers listed above 1 x Accessory pack containing instructions this document two ferrite beads for the loop cables pluggable connectors for the outreach line out relay line in microphone terminals hearing loop fitted sticker 230V 50Hz Power max 200W Fuse T 5A H 250V No user controls or user serviceable parts inside LOOP 2 OPTICAL OPTIONAL RELAY NO COM NC LINE OUT 0V A A OUTREACH 0V A A V 1 2 3...

Page 4: ...2 for alternative wall mount model connections 1 IMPORTANT DO NOT power up the system before completing Step 3 below The amplifier MUST NOT be operated without a loop connected to it Install Loop 1 Cable and Loop 2 Cable model dependent See Phased array hearing loop systems page 9 for example dual loop layouts BEFORE connecting the loops to the amplifier use a multimeter to check the loops are not...

Page 5: ... metal base securely onto a vertical wall 2m mounting height Assess the condition and construction of the wall and use suitable screw fixings for the in service weight of the product The mounting holes are suitable for use with ø4 5mm countersunk screws Any dust or swarf created during the mounting process must be kept out of the enclosure and due care must be taken not to damage any wiring or com...

Page 6: ... 2 CONNECTIONS NOT SHOWN Ensure the ferrite bead supplied is fitted at the terminal block A LOOP 1 A Loop Connectors Wall Mount Model Only Microphone Connector Wall Mount Model Only Line In Connector Wall Mount Model Only Menu Displays Use the Left and4 Right buttons to scroll through the amplifier s menu displays listed right 1 Line Input 2 Microphone 3 Phantom 4 Outreach 5 Digital model dependen...

Page 7: ... the outreach plate audio input extension system This system allows the connection of multiple microphones or line level inputs via a range of specially designed wall ceiling or desk mountable single gang plates Up to ten outreach plates any mix can be daisychained to the amplifier s outreach connector with cable lengths up to 100m total network length easily achievable using standard two pair aud...

Page 8: ...ation Note 3 Metal compensation tests must be carried out to comply with the requirements of BS EN 60118 4 Loop Drive 1 Loop Drive 2 Drive Model Dependent These menu displays are used to adjust the strength of the magnetic field generated by induction loops 1 2 by increasing the output current being driven into the loops To comply with BS EN 60118 4 Output field strength should be set up using a F...

Reviews: