Integrity Voice Alarm Routing Matrix
FMIC Manual
Page 4 of 8
DocNo.DCP0002986 ADS 11/12/05 rev0
Remove the 20 mm knock-outs, fill any unused holes with a suitable metal blank. Install the cables and
fit cable glands. Strip and connect the cables to the terminal block as shown below. If you are fitting
more than one FMIC, joint the cables in a separate connection block and then use connect to the FMIC
using short tails.
FMIC Connections
+24 V
0 V
PTT
Bus
y
Switc
h 1
Switc
h 2
A
udio +
A
udio -
+24 V
0 V
PTT
Busy
Switch 1
Switch 2
Audio +
Audio -
FMIC #1
FMIC #2
FMIC #3
FMIC #4
1
2
3
4
OFF ON
OFF ON
OFF ON
Mic
control
SW1
control
SW2
control
= ON
FMX switch settings
One FMIC fitted
Two FMICs fitted
Three FMICs fitted
Four FMICs fitted
These switch settings are IDENTICAL in
each FMIC that is connected