This chapter gives step-by-step installation instructions for 
the Converter. 

 

Selecting a Site for the Equipment 

As with any electric device, you should place the equipment 
where it will not be subjected to extreme temperatures, 
humidity, or electromagnetic interference. Specifically, the 
site you select should meet the following requirements: 
 

 

The ambient temperature should be between 32 and 104 degrees 
Fahrenheit (0 to 40 degrees Celsius). 

 

The relative humidity should be less than 90 percent, non-condensing. 

 

Surrounding electrical devices should not exceed the electromagnetic field 
(RFC) standards for IEC 801-3, Level 2 (3V/M) field strength. 

 

Make sure that the equipment receives adequate ventilation. Do not block 
the ventilation holes on each side of the equipment. 

 

The power outlet should be within 1.8 meters of the product. 

 

Connecting to Power 

This Converter is a plug-and-play device. 
 

Connect the supplied AC to DC power adaptor to the receptacle on 
the rear panel of the converter, and then attach the plug into a 
standard AC outlet with a voltage range from 100 to 240VAC. 

 

 

 

Summary of Contents for 10/100TX to 100FX

Page 1: ...Signamax Connectivity Systems 100BaseTX FX to 100BaseFX Converter Series U S E R S G U I D E ...

Page 2: ......

Page 3: ...Signamax Connectivity Systems 100BaseTX FX to 100BaseFX Converter Series User s Guide ...

Page 4: ...ial area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Signamax Connectivity Systems from Advanced Electronic Supports Products Inc All rights r...

Page 5: ...rnet Media Converter introduced here provides one channel media conversion between 10 100BaseTX and 100BaseFX The Signamax Ethernet Media Converter fully complies with IEEE802 3 10BaseT and IEEE802 3u 100BaseTX FX standards In this manual you will find Product overview Features on the media converter Illustrative LED functions Installation instructions Specifications ...

Page 6: ...ARKS 1 PREFACE 2 TABLE OF CONTENTS 3 INTRODUCTION 4 PRODUCT OVERVIEW 4 PRODUCT FEATURES 5 PACKING LIST 5 ONE CHANNEL MEDIA CONVERTER 6 PORTS 6 PORT SETTINGS 6 FRONT PANEL LEDS 7 INSTALLATION 8 SELECTING A SITE FOR THE EQUIPMENT 8 CONNECTING TO POWER 8 INSTALLING IN A CHASSIS 9 SPECIFICATIONS 9 CONTACT INFORMATION 10 ...

Page 7: ...al Introduction The media converter provides one channel for media conversion between 10 100BaseTX and 100BaseFX It can be used as a stand alone device or with a standard 19 chassis as shown below Product Overview NOTE The chassis is to be ordered separately ...

Page 8: ...ceives with 13100nm wavelength Auto negotiation of speed and duplex mode on TX port Auto MDIX on TX port One DIP switch for configuring link fault pass through fixed speed and half full duplex Store and forward mechanism Non blocking full wire speed forwarding rate Support broadcast storm filtering Back pressure IEEE802 3x compliant flow control Front panel status LEDs External AC to DC power adap...

Page 9: ...switch at the rear panel of the module 1 2 3 4 5 6 DIP switch There are six pins on the DIP switch for port settings Refer to the table below for more details DIP switch No Down Default Setting Up 1 Enable link fault pass through Disable link fault pass through 2 Enable auto negotiation for TX port Enable forced mode for TX port 3 TX port forced to 100Mbps TX port forced to 10Mbps 4 TX port forced...

Page 10: ...t Panel LEDs LED Indicators The LED indicators give you instant feedback on status of the converter LEDs State Indication Steady Power on PWR stands for POWER PWR Off Power off Steady Connection at the speed of 100Mbps 100 Mbps Off Connection at the speed of 10Mbps Steady A valid network connection established LNK stands for LINK Flashing Transmitting or receiving data ACT stands for ACTIVITY LNK ...

Page 11: ...es Fahrenheit 0 to 40 degrees Celsius The relative humidity should be less than 90 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength Make sure that the equipment receives adequate ventilation Do not block the ventilation holes on each side of the equipment The power outlet should be within 1 8 m...

Page 12: ...into the chassis directly without using the supplied carriers The carriers allow secure and consistent placement of the converters into the chassis backplane without causing any damage Specifications Applicable Standards IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX 100BaseFX Fixed Ports 1 TX port 1 FX port 10 20Mbps for half full duplex Speed 10BaseT 100BaseTX FX 100 200Mbps for half full duplex Switc...

Page 13: ... 88 Fax 46 0 293 228 89 Phone 49 81 35 9303 0 Http www aesp se E mail info aesp se JOTEC AESP AS NORWAY Telefon 23 14 17 00 Ordrefax 23 14 17 10 Karihaugveien 102 Postboks 50 Ellingsrudasen 1006 Oslo Norway Phone 47 23 14 1700 Fax 47 23 14 1710 Http www jotec no E mail jotec jotec no AESP Russia RUSSIA Kronshtadtsky Blv 125499 Moscow Russia Phone 7 095 456 0704 Phone 7 095 456 0344 Fax 7 095 454 3...

Reviews: