7

 

 

Toggle down Pin 3 to force the TX port at the speed of 100Mbps. Or toggle 
up Pin 3 for 10Mbps speed.  

 

Toggle down Pin 4 to force the TX port at full duplex mode. Or toggle up 
Pin 4 for half duplex mode. 

 

Toggle down Pin 5 to force the FX port at full duplex mode. Or toggle up 
Pin 5 for half duplex mode. 

 

Connect the converter to the power again. The new setting will come into 
effect then.  

 

Front Panel & LEDs  

LED Indicators 

The LED indicators give you instant feedback on status of the 
converter:  

 

LEDs State  Indication 

Steady Power 

on 

PWR stands for POWER 

PWR 

Off Power 

off 

Steady 

Connection at the speed of 100Mbps 

100 (Mbps) 

Off 

Connection at the speed of 10Mbps 

Steady 

A valid network connection established 
LNK stands for LINK 

Flashing 

Transmitting or receiving data 
ACT stands for ACTIVITY 

LNK/ACT 

Off 

Neither valid network connection established 
nor transmitting/receiving data. 

Steady 

Connection in full duplex mode 
FDX stands for FULL-DUPLEX 

Flashing Collision 

occurred 

COL stands for COLLISION 

FDX/COL 

Off 

Connection in half-duplex mode 

 

Summary of Contents for 10/100TX to 100FX

Page 1: ...Signamax Connectivity Systems 100BaseTX FX to 100BaseFX Converter Series U S E R S G U I D E ...

Page 2: ......

Page 3: ...Signamax Connectivity Systems 100BaseTX FX to 100BaseFX Converter Series User s Guide ...

Page 4: ...ial area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Signamax Connectivity Systems from Advanced Electronic Supports Products Inc All rights r...

Page 5: ...rnet Media Converter introduced here provides one channel media conversion between 10 100BaseTX and 100BaseFX The Signamax Ethernet Media Converter fully complies with IEEE802 3 10BaseT and IEEE802 3u 100BaseTX FX standards In this manual you will find Product overview Features on the media converter Illustrative LED functions Installation instructions Specifications ...

Page 6: ...ARKS 1 PREFACE 2 TABLE OF CONTENTS 3 INTRODUCTION 4 PRODUCT OVERVIEW 4 PRODUCT FEATURES 5 PACKING LIST 5 ONE CHANNEL MEDIA CONVERTER 6 PORTS 6 PORT SETTINGS 6 FRONT PANEL LEDS 7 INSTALLATION 8 SELECTING A SITE FOR THE EQUIPMENT 8 CONNECTING TO POWER 8 INSTALLING IN A CHASSIS 9 SPECIFICATIONS 9 CONTACT INFORMATION 10 ...

Page 7: ...al Introduction The media converter provides one channel for media conversion between 10 100BaseTX and 100BaseFX It can be used as a stand alone device or with a standard 19 chassis as shown below Product Overview NOTE The chassis is to be ordered separately ...

Page 8: ...ceives with 13100nm wavelength Auto negotiation of speed and duplex mode on TX port Auto MDIX on TX port One DIP switch for configuring link fault pass through fixed speed and half full duplex Store and forward mechanism Non blocking full wire speed forwarding rate Support broadcast storm filtering Back pressure IEEE802 3x compliant flow control Front panel status LEDs External AC to DC power adap...

Page 9: ...switch at the rear panel of the module 1 2 3 4 5 6 DIP switch There are six pins on the DIP switch for port settings Refer to the table below for more details DIP switch No Down Default Setting Up 1 Enable link fault pass through Disable link fault pass through 2 Enable auto negotiation for TX port Enable forced mode for TX port 3 TX port forced to 100Mbps TX port forced to 10Mbps 4 TX port forced...

Page 10: ...t Panel LEDs LED Indicators The LED indicators give you instant feedback on status of the converter LEDs State Indication Steady Power on PWR stands for POWER PWR Off Power off Steady Connection at the speed of 100Mbps 100 Mbps Off Connection at the speed of 10Mbps Steady A valid network connection established LNK stands for LINK Flashing Transmitting or receiving data ACT stands for ACTIVITY LNK ...

Page 11: ...es Fahrenheit 0 to 40 degrees Celsius The relative humidity should be less than 90 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength Make sure that the equipment receives adequate ventilation Do not block the ventilation holes on each side of the equipment The power outlet should be within 1 8 m...

Page 12: ...into the chassis directly without using the supplied carriers The carriers allow secure and consistent placement of the converters into the chassis backplane without causing any damage Specifications Applicable Standards IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX 100BaseFX Fixed Ports 1 TX port 1 FX port 10 20Mbps for half full duplex Speed 10BaseT 100BaseTX FX 100 200Mbps for half full duplex Switc...

Page 13: ... 88 Fax 46 0 293 228 89 Phone 49 81 35 9303 0 Http www aesp se E mail info aesp se JOTEC AESP AS NORWAY Telefon 23 14 17 00 Ordrefax 23 14 17 10 Karihaugveien 102 Postboks 50 Ellingsrudasen 1006 Oslo Norway Phone 47 23 14 1700 Fax 47 23 14 1710 Http www jotec no E mail jotec jotec no AESP Russia RUSSIA Kronshtadtsky Blv 125499 Moscow Russia Phone 7 095 456 0704 Phone 7 095 456 0344 Fax 7 095 454 3...

Reviews: