186
7 102400 102400 DISABLE 102400
8 102400 3776 DISABLE 102400
9 102400 3776 DISABLE 102400
10 102400 3776 DISABLE 102400
11 102400 3776 DISABLE 102400
12 102400 3776 DISABLE 102400
13 102400 102400 DISABLE 102400
14 102400 102400 DISABLE 102400
15 19520 102400 DISABLE 102400
16 19520 102400 DISABLE 102400
17 19520 102400 DISABLE 102400
18 19520 102400 DISABLE 102400
19 102400 102400 DISABLE 102400
20 102400 102400 DISABLE 102400
21 102400 102400 DISABLE 102400
22 102400 102400 DISABLE 102400
23 102400 102400 DISABLE 102400
24 102400 102400 DISABLE 102400
25 1024000 1024000 DISABLE 1024000
26 1024000 1024000 DISABLE 1024000
set storm
Syntax
:
set storm <range> <type> < rate>
Description
:
To set up the storm control of the ports.
Argument
:
<range>:syntax: 1,5-7, available from 1 to 26
<type>:
0 - Disable
1 - BC for broadcast storm
2 - UC for unicast storm
3 - BC,UC for both broadcast and unicast storm
4 - MC for multicast storm
5 - BC,MC for both broadcast and multicast storm
6 - UC,MC for both unicast and multicast storm
7 - BC,UC,MC for broadcast, unicast and multicast storm<data_rate>: 1-100.
<rate>: 64 - 1024000 (Kbps).
FE port: 64 - 102400 (Kbps)
GE port: 64 - 1024000 (Kbps).
Possible value:
<range>: 1 to 26
<type> : 0 to 7
<rate>: 64- 1024000 (Kbps)
Example:
065-7727S(bandwidth)# set storm 20 3 5000
065-7727S(bandwidth)#
show
Port Ingress Rate(Kb) Egress Rate(Kb) Storm Type Storm Rate(Kb)