SignaMax 065-7418POETB User Manual Download Page 14

Signamax

 Hardened PoE Ethernet Switch 

12                                                                               User’s Manual 

There are two pins on the terminal block are used for power 
failure detection. Use this as a dry contact application to send 
a signal for power failure detection. 

 

Power Input Assignment 

Power2 

 

47-57VDC 

Terminal Block 

 

Power Ground 

Power1 

 

47-57VDC 

 

Power Ground 

 

Earth Ground 

Relay Output Rating 

1A @ 24VDC 

 
 

Connecting to Your Network 

Cable Type & Length 

It is necessary to follow the cable specifications below when 
connecting the switch to your network. Use appropriate 
cables that meet your speed and cabling requirements. 

 

Cable Specifications 

Speed 

Connector 

Port Speed 
Half/Full 
Duplex 

Cable 

Max. 
Distance 

10BaseT 

RJ-45 

10/20 Mbps 

4-pair UTP/STP 
Cat. 3, 4, 5 

100 m 

100BaseTX 

RJ-45 

100/200 Mbps 

4-pair UTP/STP 
Cat. 5 

100 m 

1000BaseT 

RJ-45 

2000 Mbps 

4-pair UTP/STP 
Cat. 5 

100 m 

1000BaseSX 

SC, ST 

2000 Mbps 

MMF (50 or 

62.5μm)

 

275, 550 m 

1000BaseSX 

SC 

2000 Mbps 

MMF (50 or 

62.5μm)

 

2 km 

1000BaseLX 

SC 

2000 Mbps 

SMF (9 or 10

μm)

 

10, 20 km 

1000BaseBX 

SC 

2000 Mbps 

SMF (9 or 10

μm)

 

20 km 

SFP 
1000BaseSX 

Duplex LC 

2000 Mbps 

MMF (50 or 

62.5μm)

 

275 m, 550 
m, 2 km 

1000BaseLX 

Duplex LC 

2000 Mbps 

SMF (9μm)

 

10,  20,  40, 
70 km 

1000BaseBX 

Single LC 

2000 Mbps 

MMF (50 or 

62.5μm)

 

550 m 

1000BaseBX 

Single LC 

2000 Mbps 

SMF (9μm)

 

10, 20 km 

  

Summary of Contents for 065-7418POETB

Page 1: ...Signamax Connectivity Systems Hardened PoE Ethernet Switch Series U S E R S G U I D E ...

Page 2: ...Signamax Connectivity Systems Hardened PoE Ethernet Switch Series User s Guide ...

Page 3: ... area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Signamax Connectivity Systems from Advanced Electronic Supports Products Inc All rights rese...

Page 4: ...ustrial environment Supports IEEE802 3at Power over Ethernet PoE Power Sourcing Equipment PSE 1000Mbps Full duplex 10 100Mbps Full Half duplex Auto Negotiation Auto MDI MDIX Supports 4096 MAC addresses Provides 2 25M bits buffer memory Alarms for power failure by relay output Power Supplies Redundant 47 57VDC Terminal Block power inputs Operating voltage and Max current consumption 9A 55VDC Power ...

Page 5: ...on Gigabit Ethernet Link ACT Steady A valid network connection established Flashing Transmitting or receiving data ACT stands for ACTIVITY TX Steady A valid TX connection established Off No valid TX connection established SFP Steady A valid SFP connection established Off No valid SFP connection established DC Terminal Block Power Inputs There are two pairs of power inputs can be used to power up t...

Page 6: ...C 2 The 1000BaseT Connections The following lists the pinouts of 1000BaseT ports Pin Signal Name Signal Definition 1 TP0 Transmit and Receive Data 0 2 TP0 Transmit and Receive Data 0 3 TP1 Transmit and Receive Data 1 4 TP2 Transmit and Receive Data 2 5 TP2 Transmit and Receive Data 2 6 TP1 Transmit and Receive Data 1 7 TP3 Transmit and Receive Data 3 8 TP3 Transmit and Receive Data 3 3 The SFP Soc...

Page 7: ...iber port pinouts The Tx transmit port of device I is connected to the Rx receive port of device II and the Rx receive port of device I to the Tx transmit port of device II 5 The WDM 1000BaseBX Connections The fiber port pinouts Only one optical fiber is required to transmit and receive data ...

Page 8: ...rts IEEE802 3at Power over Ethernet PoE Power Sourcing Equipment PSE and can detect an IEEE802 3at compliant Powered Device PD Using external 47 57VDC power inputs through Terminal Block data and power can be transmitted to a Powered Device PD over the same twisted pair Ethernet cable through port 1 to port 16 on the Switch This manual describes how to install and use the hardened Ethernet Switch ...

Page 9: ...L DESCRIPTION 2 PHYSICAL DESCRIPTION 2 PREFACE 6 TABLE OF CONTENTS 7 PRODUCT OVERVIEW 8 HARDENED POE ETHERNET SWITCH 8 PACKAGE CONTENTS 8 PRODUCT HIGHLIGHTS 8 FRONT PANEL DISPLAY 9 PHYSICAL PORTS 10 INSTALLATION 11 SELECTING A SITE FOR THE EQUIPMENT 11 CONNECTING TO POWER 11 CONNECTING TO YOUR NETWORK 12 SPECIFICATIONS 14 CONTACT INFORMATION 16 ...

Page 10: ... control equipment Meets EN61000 6 2 EN61000 6 4 EMC Generic Standard Immunity for industrial environment Supports IEEE802 3at Power over Ethernet PoE Power Sourcing Equipment PSE 1000Mbps Full duplex 10 100Mbps Full Half duplex Auto Negotiation Auto MDI MDIX Supports 4096 MAC addresses Provides 2 25M bits buffer memory Alarms for power failure by relay output Power Supplies Redundant 47 57VDC Ter...

Page 11: ...mitting or receiving data ACT stands for ACTIVITY 10 100 Steady Valid port connection at 100Mbps Off Valid port connection at 10Mbps PoE Steady Powered device PD is connected Off Powered device PD is disconnected LED State Indication Gigabit Ethernet Link ACT Steady A valid network connection established Flashing Transmitting or receiving data ACT stands for ACTIVITY TX Steady A valid TX connectio...

Page 12: ...E ports 2 x Gigabit Ethernet ports 12 x 10 100BaseTX PoE ports 2 x Gigabit Ethernet ports 8 x 10 100BaseTX PoE ports 2 x Gigabit Ethernet ports Connectivity RJ 45 connectors SC or ST connector on 1000BaseSX LX fiber port SC connector on 1000BaseBX fiber port SFP socket connection on 1000BaseSX LX BX fiber port Note Different product model supports different type of fiber connector ...

Page 13: ...n 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards Make sure that the equipment receives adequate ventilation Do not block the ventilation holes on each side of the equipment The power outlet should be within 1 8 meters of the product Connecting to Power Redundant DC Terminal Block Power Inputs Redundant DC Terminal Block Power Inpu...

Page 14: ...cables that meet your speed and cabling requirements Cable Specifications Speed Connector Port Speed Half Full Duplex Cable Max Distance 10BaseT RJ 45 10 20 Mbps 4 pair UTP STP Cat 3 4 5 100 m 100BaseTX RJ 45 100 200 Mbps 4 pair UTP STP Cat 5 100 m 1000BaseT RJ 45 2000 Mbps 4 pair UTP STP Cat 5 100 m 1000BaseSX SC ST 2000 Mbps MMF 50 or 62 5μm 275 550 m 1000BaseSX SC 2000 Mbps MMF 50 or 62 5μm 2 k...

Page 15: ...nstallation Step 2 Prepare cable with corresponding connectors for each type of port in use Step 3 Consult the previous section for cabling requirements based on connectors and speed Step 4 Connect one end of the cable to the switch and the other end to a desired device Step 5 Once the connections between two end devices are made successfully turn on the power and the switch is operational ...

Page 16: ...1000Mbps Cable 10BaseT 100BaseTX 1000BaseT 100BaseFX BX 1000BaseSX LX BX 4 pair UTP STP Cat 3 4 5 4 pair UTP STP Cat 5 4 pair UTP STP Cat 5 Up to 100m 328ft MMF 50 or 62 5μm SMF 9 or10μm MMF 50 or 62 5μm SMF 9 or10μm LED Indicators Per unit Power status Power1 Power2 Fault Per port 10 100TX Link ACT 10 100 PoE Gigabit Ethernet Link ACT TX SFP Dimensions 17 4 W x 8 07 D x 1 73 H 442mm W 205mm D 44 ...

Page 17: ...Standards EN61000 4 4 Burst Standards EN61000 4 5 Surge Standards EN61000 4 6 Induced RFI Standards EN61000 4 8 Magnetic Field Standards Environmental Test Compliance IEC60068 2 6 Fc Vibration Resistance IEC60068 2 27 Ea Shock IEC60068 2 32 Ed Free Fall NEMA TS1 2 Environmental requirements for traffic control equipment ...

Page 18: ...ual Contact Information SIGNAMAX CONNECTIVITY SYSTEMS An AESP Company 16295 N W 13h Avenue Miami Florida 33169 U S A Phone 305 944 7710 Fax 305 652 8489 Sales 800 446 2377 Tech Support 800 446 2377 ext 201 E mail Http www signamax com info signamax com ...

Reviews: