14 

 

Hardware Installation 

Installation Steps 

This  section  will  explain  how  to  install  the  Signamax  065-7407GPOEP  7-port  industrial  PoE+ 
gigabit unmanaged Ethernet switch. 
 

Installation Steps 

Step 1

 

Unpack the 065-7407GPOEP switch from the original packing box. 

Step 2

 

Check if the DIN-Rail bracket is screwed on the switch.  

 

If  the DIN-Rail  is not  screwed on the  switch, please  refer  to the 

DIN-Rail  Mounting

 

section for DIN-Rail installation.  

 

If you want to wall mount the switch, please refer to the 

Wall Mounting

 section for 

wall mounting installation. 

Step 3

 

To  hang  the  switch  on  a  DIN-Rail  or  wall,  please  refer  to  the 

Mounting  Installation

 

section. 

Step 4

 

Power on the switch, and then the power LED light will turn on. 

 

If you need help on how to wire power, please refer to the 

Wiring the Power Inputs

 

section.  

 

Please refer to the 

LED Indicators

 section for LED light indication. 

Step 5

 

Prepare  the  twisted-pair,  straight-through  category  5e  or  better  cable  for  Ethernet 

connection. 

Step 6

 

Insert one side of the RJ-45 cable into switch’s Ethernet port and on the other side 

into  the  networking  device’s  Ethernet  port,  e.g.  switch,  PC,  or  server.  The  Ethernet 
port’s  (RJ-45)  LED  on  the  industrial  Ethernet  switch  will  turn  on  when  the  cable  is 

connected to the networking device.  

 

Please refer to the 

LED Indicators

 section for LED light indication. 

Step 7

 

When all  connections  are  set  and the  LED  lights  all  show  normal, the  installation  is 
complete. 

 

 

Summary of Contents for 065-7407GPOEP

Page 1: ...065 7407GPOEP User Manual Last Update July 8 2015 Version 1 0...

Page 2: ...hts 2015 by Signamax Inc All rights reserved Reproduction adaptation or translation without prior permission of Signamax Inc is prohibited except as allowed under the copyright laws Disclaimer Signama...

Page 3: ...ne or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different f...

Page 4: ...cal Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 5 Cabling 7 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 10 Mounting Installation 11 DIN Rail Mounting 11 Wall Mou...

Page 5: ...erts users about power failures that occur This model has a wide operating temperature of 40 F 167 F 40 C 75 C and is designed to meet any needs for industrial automation outdoor application and harsh...

Page 6: ...brackets and screws 1 DC cable 18 AWG DC jack 5 5x2 1mm Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The in...

Page 7: ...Description Physical Dimensions Figure 2 1 below shows the physical dimensions of the Signamax 065 7407GPOEP 7 port industrial PoE gigabit unmanaged Ethernet switch Figure 2 1 065 7407GPOEP Physical...

Page 8: ...witch is shown below in Figure 2 2 Figure 2 2 The Front Panel of 065 7407GPOEP Top View Figure 2 3 below shows the top panel of the 065 7407GPOEP switch that is equipped with one 6 pin removal termina...

Page 9: ...to the powered device Off No powered device attached or power supplying fails LNK ACT SFP Port Green On Connected to network Flashing Networking is active Off Not connected to network LAN Port 1 5 Le...

Page 10: ...nd 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 shows the 10BASE T 100BASE TX 1000BASE TX MDI and MDI X port pin...

Page 11: ...the link partner switch hub workstation etc must be less than 100 meters 328 ft long The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telec...

Page 12: ...9 Transceiver to the SFP Module Figure 2 10 Transceiver Inserted Step 2 Insert the fiber cable of the LC connector into the transceiver as shown below in Figure 2 11 Figure 2 11 LC Connector to the T...

Page 13: ...LC Connector Step 2 Push down the metal clasp and pull the transceiver out by the plastic part as shown below in Figure 2 13 Figure 2 13 Pull Out from the SFP Module Wiring the Power Inputs Please fo...

Page 14: ...the terminal block connector as the picture shows below in Figure 2 16 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch on...

Page 15: ...gure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to mount the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear...

Page 16: ...ll Mounting Follow the steps below to mount the industrial Ethernet switch using the wall mounting bracket as shown below in Figure 3 4 Step 1 Remove the DIN Rail bracket from the industrial Ethernet...

Page 17: ...he wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail Bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounti...

Page 18: ...ounting Installation section Step 4 Power on the switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Please refer...

Page 19: ...ssist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicatio...

Page 20: ...point alternative A mode Positive VCC Pin 1 2 Negative VCC RJ 45 pin 3 6 Data Pin 1 2 3 6 SFP Slot 2 SFP slots supporting dual rate 100 1000Base SFPs LED Power Unit P1 Green P2 Green fault Red Etherne...

Page 21: ...9mm D x 142mm H EMI FCC Class A CE EN61000 4 2 3 4 5 6 8 11 12 CE EN61000 6 2 CE EN61000 6 4 Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Safety UL 508 Pending...

Reviews: