Signamax 065-1063FSx series RS-232/422/485 to 100Base/FX Device Server / Media Converter
23
The options for configuring community strings and related trap functions are described
as below.
Use the <Tab> and <Enter> keys as previously. Enter the IP address of computers for
when abnormalities on a connection occur and an alarm to be sent. Enter their
community names and disable or enable their alarm function accordingly. See
descriptions below:
Parameter
Description
Index
Status
IP Address
Community
Number assigned to each trap
Disable or enable their alarm function accordingly
Enter the IP address of computers for when abnormalities on
a connection occur and an alarm to be sent. Enter their
community names and disable or enable their alarm function
accordingly
Enter their community names
You can use an external SNMP-based application to configure and manage the Device
Server / Managed Media Converter. This management method requires the SNMP
agent on the Device Server / Managed Media Converter and the SNMP Network
Management Station to use the same community string. This management method, in
fact, uses two community strings: the get community string and the set community
string. If the SNMP Network Management Station only knows the set community string,
it can read and write to the MIBs. However, if it only knows the get community string, it
can only read MIBs.
The default Get and Set community strings for the product
are public.