Signamax 065-1063FSx series RS-232/422/485 to 100Base/FX Device Server / Media Converter
19
Applications for Operation Modes:
Device Server Mode:
In this mode the Device Server acts in the Server role of the
RFC-2217 COM Port Control Protocol.
Converter Mode:
In this mode the Device Server acts like an advanced media
converter.
Like a normal converter, the Device Server communicates with a remote
Device Server in a peer-to-peer way. Also, the Device Servers communicate with each
other through an IP network in the TCP communication model. The TCP Client and
Server roles of the two Device Server peers are negotiated automatically.
Diagram 2 – Peer-to-Peer Application (Converter Mode)
Serial
Cable
Serial
Cable
PC
IP
Network
TCP Connection
PLC
Device
Server
Device
Server
Diagram 1 – Central Management Application (Device Server Mode)
Serial
Cable
IP Virtual COM port Software
IP
Network
TCP Connections
LAN
Serial
Cable
Serial
Cable
PLC
PLC
PLC
Device
Server
Device
Server
Device
Server