background image

Installation & User Manual 

 

 

 

60dB, as a result, the isolation required between the subscriber and 

the donor antenna is in a range of 70dB.  The line of sight separation 

between the subscriber (indoor) and donor (outdoor) antennas 

represented by a free space loss of 70dB within a building is 17 

meters (55 feet).  The separation distance can be reduced if the donor 

antenna is mounted on the building exterior (i.e. on a roof), or using a 

directional donor antenna (narrow beam width).  For example, if a 

metal roof separates the indoor and outdoor antennas, the physical 

separation may be substantially reduced.  

 

The following table indicates separation distances for different 

installation configurations: 

 

 

Line of Sight in-

building  

Exterior Donor Antenna, 

with 20dB Attenuation

1

 

Exterior mounted 

Directional Antenna

2

 

Separation 

Distance 

meters (ft) 

17 (55) 

8 (26) 

4 (13) 

1

 

The attenuation is indicative of the construction material that a signal has to penetrate 

through

 

2

 As in 

1

, but using a directional antenna with a typical front to back ratio of 20dB 

 

It is not recommended that the donor (outdoor) and subscriber 

(indoor) antennas be installed within sight of each other.  Do not install 

the unit where a skylight or other low loss RF path exists between the 

donor or subscriber antenna.  Arrista recommends that the donor 

(outdoor) antenna be installed on the roof or on an outside wall of a 

building.  A cell phone can be used to determine if an adequate signal 

is present at the chosen location.  Run a length of 50-ohm cable 

between chosen location and the repeater unit.   

 

Cable Length  Recommended Cable 

< 50 ft 

Andrew CNT-100, CNT-200 

Times Microwave LMR-240, or equiv. 

50 – 100 ft 

Andrew CNT-400 

Times Microwave LMR-400, or equiv. 

> 150 ft 

Andrew CNT-600 or equivalent 

 

Select a suitable location for the subscriber (indoor) antenna, and 

connect it to the 

Ant 1

 port of the repeater. 

 

If only one subscriber (indoor) antenna is to be used, flip the switch to 

the left to disable the second subscriber port. 

Copyright © 2004 Arrista Technologies Inc.  All rights reserved. 

5

 

Summary of Contents for CR300

Page 1: ...CR300 Bi Directional Repeater Installation User Manual www signalreach com ...

Page 2: ...ay 2004 Copyright1 Printing2Legal statements3 1Copyright 2000 2004 SignalReach Inc All Rights Reserved 2Printed in Canada 3Information is subject to change without notice Arrista Technologies Inc reserves the right to make changes in design or components as progress in engineering and manufacturing may warrant ii ...

Page 3: ..._________________________________________________4 Fault Reporting _____________________________________________________________________7 Operation __________________________________________________________________________7 Product Maintenance_________________________________________________________________7 Troubleshooting _____________________________________________________________________8 Cop...

Page 4: ...oving coverage of existing service by increasing the signal strength in dead spots The repeater is a network compatible device that amplifies cellular signals in both the uplink and downlink directions The repeater is simple to install and contains circuitry to ensure proper operating power levels and as well includes an automatic feedback and detection circuitry that detects poor isolation betwee...

Page 5: ...located outside the building Signals from the cellular tower downlink are also amplified and passed to the subscriber antenna The SignalReachTM CR300 in building repeater is a Class B Broadband device and processes the iDEN SMR 806 825 851 870 MHz band Input and output duplexers and band pass filters in the downlink and uplink path provide the repeater s filtering and isolation The maximum gain in...

Page 6: ...llular indoor downlink antenna gain authorized shall be limited to 9 dBi or less in order to meet RF exposure MPE limit as per FCC guidelines When servicing or installing outdoor transmitting elements i e antennas all transmitting signal sources should be turned off in order to meet RF exposure MPE limit as per FCC guidelines The repeater unit should be installed in a sheltered area as it is not s...

Page 7: ...a signal has to penetrate through 2 As in 1 but using a directional antenna with a typical front to back ratio of 20dB It is not recommended that the donor outdoor and subscriber indoor antennas be installed within sight of each other Do not install the unit where a skylight or other low loss RF path exists between the donor or subscriber antenna Arrista recommends that the donor outdoor antenna b...

Page 8: ...inguish The normal operating condition is a green power LED with an extinguished status LED If the status LED is amber and flashing either an isolation problem exists or too much signal is being received at the outdoor antenna To solve this problem try relocating the antenna or rotate the antenna for directional antennas until the amber LED extinguishes If the status LED is green and flashing eith...

Page 9: ...ch to allow a user to connect additional subscriber antenna on the repeaters secondary port to increase coverage area The front panel has two LEDs A green Power LED indicates that the repeater is operating The Status LED indicates several conditions consult the troubleshooting section for details Product Maintenance The CR300 does not require maintenance as long as it is properly installed followi...

Page 10: ...antenna to reduce gain Power LED is on status LED is green and flashing The repeater has reduced its uplink gain to maintain network compatibility This is usually caused by a handset being used too close to the interior antenna None The repeater will automatically return to full gain when conditions permit If the condition persists when no handset is nearby relocate the indoor and or outdoor anten...

Page 11: ...tion is for a multi carrier environment of up to 3 simultaneous TDMA carriers or 1 CDMA Carrier General Specifications Power Requirements 12V DC 0 5 Amp typical 1 0 Amp max Remote Alarm Output An open collector output third pin in the power connector Contact rating 12V 200mA Pin is at ground potential on fault condition Operating Temperature Range 40 to 60 C 40 to 128 F indoor use only Dimensions ...

Page 12: ...Installation User Manual Copyright 2004 Arrista Technologies Inc All rights reserved 1 ...

Reviews: