![SignalReach CR300 Installation & User Manual Download Page 11](http://html.mh-extra.com/html/signalreach/cr300/cr300_installation-and-user-manual_1268336011.webp)
Installation & User Manual
RF Specifications
Uplink
Downlink
Frequency Range
806-825 MHz
851-870 MHz
Typical Output Power
1
+ 23dBm
+15dBm
Typical Gain
60 dB
60 dB
Maximum Allowable Antenna
Gain
18 dBi
9 dBi
Poor Isolation Detection &
Warning Indicator
If re-generative feedback between indoor and outdoor
antennas is detected, condition will be indicated with an amber
LED indicator
Maximum Possible Exposure
(MPE)
Human exposure to non-ionizing radiation meets or exceeds
the permissible FCC mandated MPE specification
1
The RF output power specification is for a multi-carrier environment of up to 3 simultaneous TDMA carriers or 1 CDMA Carrier
General Specifications
Power Requirements
12V DC, 0.5 Amp typical, 1.0 Amp max
Remote Alarm Output
An open collector output, third pin in the power connector.
Contact rating: 12V, 200mA. Pin is at ground potential on fault
condition.
Operating Temperature
Range
-40 to +60
°
C (-40 to 128
°
F), indoor use only
Dimensions
161mm L x 152mm W x 33mm H (6.38” L x 5.98” W x 1.30” H) without
RF connectors
Net Weight
1.5 kg (3.2 lbs)
RF Connectors
TNC Female
Subscriber Antenna
Customer Supplied
Donor Antenna
Customer Supplied
Included Accessories
120V AC adapter, the adapter complies to UL and CSA safety
standards
Copyright © 2004 Arrista Technologies Inc. All rights reserved.