Signal Wizard Systems Vsound 2 Manual Download Page 15

15 

 

 

 

12.

 

Hardware specifications 

 

Hardware 

 

Stomp-box design 

 

Large 2-digit 7-segment LED display 

 

Foot switches: violin select and bypass/toggle 

 

Standard quarter inch mono phono sockets 

 

Output to amplifier or headphones 

 

Rotary volume control 

 

9V DC input, centre negative 

 

Current consumption: 200 mA 

 

Micro USB socket 

 

Dimensions (mm): L127 x W94 x H42 

 

Weight: 315 grams 

 
Analogue system 

 

24-bit sigma delta codec (ADC, DAC), 36 kHz sample rate 

 

Single channel input 

 

Gain switchable pre-amplifier, 0 dB and 14 dB 

 

Input impedance: 500 kΩ

 

 

Output: audio power amplifier, 250 mW per channel of continuous average power to an 8X load 
with 0.1% (THD). 

 

Full scale input/output voltage range, V (peak-to-peak), typical: ±1.8 V 

 

Noise: <1 mV RMS, codec sample rate of 36 kHz 

 

System latency, bypass: 0.68 milliseconds 

 

System latency, IR: 1.80 milliseconds 

 
Processor system 

 

Clock Speed: 200 MHz 

 

Enhanced Filter Co-Processor (EFCOP) 

 

400 MMAC 

 

24-bit resolution (56-bit intermediate) 

 

Highly parallel instruction set with unique DSP addressing modes 

 

Two 56-bit accumulators including extension byte 

 

Two parallel 24 X 24-bit multiply-accumulates in 1 instruction cycle (1 clock cycle) 

 

Double precision 48 X 48-bit multiply with 96-bit result in 6 instruction cycles 

 

56-bit addition/subtraction in 1 instruction cycle 

 

Fractional arithmetic with support for multi-precision arithmetic 

 

Hardware support for block-floating point FFT 

 

Hardware nested DO loops 

 

Digital Phase Locked Loop (PLL) clock multiplier  

Summary of Contents for Vsound 2

Page 1: ...1 Vsound 2 Manual Revision 2 5 Mac OSX version Signal Wizard Systems...

Page 2: ...System 6 Response control 7 Spectrum EQ 8 Changing default axes 10 Selecting an impulse response from the software 11 Batch file utility 12 Updating the operating system and factory defaults 13 About...

Page 3: ...er volume control a unique high precision equaliser and an adjustable blender The blender which combines the original with the processed signal extends the scope of the system for use with acoustic in...

Page 4: ...lect the IR The pedal can hold 10 IRs in its memory and the footswitch cycles round from 0 bypass to 10 Bypass toggle This footswitch toggles between bypass and the presently selected IR Front panel I...

Page 5: ...ble provided The drivers for the USB communication will automatically be installed from the internet Do not proceed until this stage has been completed Click the Detect button in the Notifications and...

Page 6: ...version of the firmware operating system to be updated or reloaded Also allows the pedal to be reset to its factory default state Digital volume buttons these increase or decrease the digital volume i...

Page 7: ...Grid toggles the grid on the frequency response and impulse response plots Clear clears the impulse and frequency response plots and internally closes the associated impulse response file Frequency a...

Page 8: ...g Now using the mouse wheel roll it forwards or backward to increase or decrease the gain of the highlighted region if you are using the mouse pad use a two finger swipe up or down If you want to EQ a...

Page 9: ...ble To avoid this artefact set the precision to high The EQ will adapt the gain of the frequency response so that the IR has no ripples Shaping by default this is set to curved This means that the gai...

Page 10: ...Axes A new window opens which you can use to change the vertical axis range of the impulse response and frequency response plots For the frequency response plot two ranges are provided depending on wh...

Page 11: ...l will always remember the most recently selected response and use this on power up or after a reset When an IR is selected it is also plotted as an impulse response and frequency response in the norm...

Page 12: ...select and add any IR to the list Open batch opens a batch file which contains a list of IRs that you created previously Clear clears all of the IRs from the list Remove file removes the IR that has...

Page 13: ...the version on the web has a higher number then download it and save it to the vsound folder To update or restore the OS select Tools System from the main menu A window will open called Update operati...

Page 14: ...rs a violin characterization service to provide our customers with impulse responses of their favourite acoustic violins For more details please contact us through our website www signalwizardsystems...

Page 15: ...ll scale input output voltage range V peak to peak typical 1 8 V Noise 1 mV RMS codec sample rate of 36 kHz System latency bypass 0 68 milliseconds System latency IR 1 80 milliseconds Processor system...

Page 16: ...on Autosave all settings Gain adjustment and full digital gain Blender control wet dry balance Detailed impulse and frequency response display with zoom Spectrum EQ with save configuration Full real t...

Page 17: ...mail signalwizardsystems com Sales sales signalwizardsystems com Web www signalwizardsystems com Facebook www facebook com VsoundSWS Tel 44 161 306 4906 Company details Copyright 2019 Signal Wizard Sy...

Page 18: ...el the purchase of a good without having to give a reason at any time within the cooling off period of seven working days beginning on the day after you receive the goods If you are in possession of t...

Reviews: