background image

Technical description and operating manual ST 167 and ST167W5 

 

 

2 FUNCTIONALITY 

ST167 is designed for: 

 

 

Detection,  identification  and  localization  of  the  sources  of  the  following  types  of  signals:  cellular 

standards (cellular phones and modems SDMA450, GSM 900, 1800, 3,4 and 5G), wireless data transmission 

(WLAN 2.4 and 5GHz , BLUETOOTH) and microcellular wireless communication standard DECT. 

 

All the devices mentioned above hereafter are referred to as DRT (digital radio transmitters).  

 

Spectrogram  standards  indication  is  provided,  including  channels  separation  in  3G,  4G,  WLAN  and  DECT 

standards. 

  

Data transmission intensity analysis is provided for the WLAN standard.  

 

Special SMS detection mode is provided. 

 

Furthermore, BASE STATIONS signal level indication in CDMA450, GSM 900, 1800, 3, 4, 5G and DECT 

standards is possible.  

 
 

 

Access  points(routers)  indication,  their  name,  MAC  address,  used  channel  number  and  signal  level  in 
WLAN 80.1 (a,b,g,n) range (only for ST167W5). 
 

 

Detection and  measurement of  frequency, demodulation (AM and FM) and  locating  of the sources  of 
analog  signals  (hereinafter  referred  to  as  ART,  i.e.,  analog  radio  transmitters).  You  can  choose  the 
threshold, the scanning range and the sound control of the demodulated signals. 

 

Blockers (jammers) detection of GSM and GPS standards 

 

 

External  devices  control,  including  additional  indication  devices  and  jammers/blockers  of  cellular  and 
wireless data transfer (Additional optional - the letter “R” is added to the device name). 

 

 

Vibrating alert (Additional optional - the letter “V” is added to the device name). 

 

Round the clock monitoring of radio environment while registering the information on the detected 

signals in non-volatile memory of the unit. 

 

Special  software  application  «ST167  Analyzer»  extends  unit  configuring  possibilities,  visualizing  and 

saving the data. 

 
 
 
 
 

Summary of Contents for ST167

Page 1: ...ST 167 BETTA ST167W5 SEARCH RECEIVER TECHNICAL DESCRIPTION AND OPERATING MANUAL...

Page 2: ...ATION MODE 8 6 4 MANUAL OPERATION MODE 12 6 5 SEARCH OPERATION MODE 12 6 6 EVENT LOG OPERATION MODE 13 6 7 SMS GPRS OPERATION MODE 14 6 8 Wi Fi OPERATING MODE only for ST167W5 15 6 9 BASE STATIONS LEV...

Page 3: ...e of ST167 ST167W5 hereinafter ST167 if isn t otherwise noted Carefully read it before using and keep it as your further reference manual The information contained in this document is subject to chang...

Page 4: ...ds is possible Access points routers indication their name MAC address used channel number and signal level in WLAN 80 1 a b g n range only for ST167W5 Detection and measurement of frequency demodulat...

Page 5: ...dication color OLED display 160X128 3 9 Internal power supply Li pol acc battery 3 6 V 3 10 Current consumption mA 450 3 11 Dimensions of the main unit mm 90x54x21 3 12 Dimensions of the package mm 12...

Page 6: ...hin a given range of analog signals The signals exceeding a predetermined threshold are shown in the screen and the information on the detected signals is recorded in the event log 5 1 2 The MANUAL mo...

Page 7: ...l see 6 1 2 and a clock The line at the bottom of the screen displays associative alpha numerical characters for DRT 9 GSM900 B8 18 GSM1800 B3 D DECT 3G CDMA450 B31 3G 2100 B1 3G 900 B8 4G 3G 4G1800 B...

Page 8: ...the located on the side of the main unit Once completed the indicator light goes out Full charge when the unit is turned off takes about four hours When the unit is turned on the battery can be charg...

Page 9: ...select a desired standard Selection of the threshold value can be selected individually for each standard DRT The lower the number on the right side of the display the higher the sensitivity Select t...

Page 10: ...n in red Fig 7 Fig 7 Pressing the button provides a transition to a spectrogram with a frequency range corresponding to this standard except CDMA BLUETOOTH and blockers Figure 8 shows the screen displ...

Page 11: ...ency of the signal with the larger level to be displayed Figure 11 Additional information The appearance of the red triangle in the top right corner of the display indicates the change in the gain of...

Page 12: ...lators the indication level corresponds to the last measured value and does not change until the state Demodulation OFF is selected This turns on the audio monitoring the icon changes to the icon fig...

Page 13: ...ormation on the detected signal is displayed on the screen such as shown in the Fig 18 6 7 SMS GPRS OPERATION MODE This mode is intended for short SMS messages and short messages in GPRS protocol whic...

Page 14: ...el set up is done in MENU Threshold and choosing of needed standard 6 8 WORKING IN WiFi MODE only for ST16W5 Entering this mode is done by selecting WiFi line in MENU After Wi Fi network selection by...

Page 15: ...signals from other radio emitting devices using Wi Fi range Ability of 2 signal level values operational control fig 25 and 26 gives wide ability range for Radio emitting devices detection in WiFi net...

Page 16: ...which should be blocked In case of possibility to it by blocker itself GSM 900 1800 and 3G standards can be seen on fig 30 To suppress unwanted communication session blocker should have the following...

Page 17: ...age TABLE 1 Band Option Description Value Default settings Region Select the region in which the devicde is used ALL Europe South Korea Americas Europe Cellurar The choice of cellular ranges B1 2100 B...

Page 18: ...threshold 45 Setting the traffic 5GHz intensity threshold from 1 to 100 45 Bluetooth Set Bluetooth 1 detection threshold 0 50 20 Set Bluetooth 1 detection threshold from 80 to 45dB 55dB Jammers Set GS...

Page 19: ...e in fact without sorting as the events come with time Selected By level sorting the maximum level in descending order Not selected By the type of signal Not selected By duration sorting by event dura...

Page 20: ...the time for a single or daily recording in the event log Turn ON OFF 0 23hours Not selected Once or daily Selected not selected Set clock Setting date and time When the power is OFF the time is clea...

Page 21: ...aximum power of GSM transmitter 2W with maximum distance from the base station Minimum real power of 3G and 4G transmitters microwatts with minimum distance from the base station Extreme cases both la...

Page 22: ...her Emitted power of devices with 3G transmitter is significantly lower and respectively detection range will be much smaller DECT For listening and data transfer mobile phones with room listening or...

Page 23: ...orks Three main methods RD detection is considered 1 Based on displacement of ST167 for detection of active at search moment RD location 2 Using of AUTO mode with stationary position of ST167 Given me...

Page 24: ...is signals can be low power device using WI FI or other radio standards including BLUETOOTH By pressing button to visible 2 4 and 5 GHz ranges spectrogram indication can be done This will allow to est...

Page 25: ...l WIFI 2 4GHz range Total amount of channels in this range 14 In Russia 13 and 14 channels are not in use In USA 11 14 channels are not in use what makes impossible to use for example Iphone with this...

Page 26: ...evices of this standard varies from relatively high tens of milliwatts data transfer and hundreds of microwatts wireless headset cell phones An additional detection complexity is the FHSS with a band...

Page 27: ...e from the radio transmission device emitted power located on a specific distance from ST167 and signal level on ST167 display This data is for 1000MHz frequency This table data is estimates and do no...

Page 28: ...ould be minimized during search process 7 5 BLOCKER JAMMER DETECTION Blockers can be used for channel signals GSM alarm systems signals vehicle alarms suppression 8 1 SOFTWARE ST167Analyzer 8 1 1 Purp...

Page 29: ...18 00 a signal was recorded on a GSM900 channel lasting 15 seconds then a rectangle opposite the inscription GSM900 will appear on the diagram which will start at 18 00 00 on the X scale and end at 18...

Page 30: ...l the information received from ST167 in real time approximately 3 measurements per second Using the New Folder button you can create a folder in the current storage folder Using the Rename button you...

Page 31: ...tion of cellular standards at the place of use of ST167 the device ST181 Base Station Analyzer is intended Menu settings can be saved Save button and loaded from a file Download button The menu file e...

Page 32: ...7 to the computer using the USB cable When prompted for driver installation enable the installation Run the installer Check the download process on the computer screen 9 LIMITATIONS AND RECOMMENDATION...

Page 33: ...cement if necessary 10 3 Gratuitous repair and adjustment or replacement are possible in case the consumer has followed the rules of use transportation and storage the unit and its subsidiary parts ha...

Reviews: