8.2
Performance Level e, Category 3 or SIL 3
– Safety-SPS
To meet the requirements of safety category 3, performance level "e" for EN ISO 13849-1
and SIL 3 according to EN 62061, an error-proof output of a safety PLC must be used. The
reason for category 3 here, is because cross-circuit detection between the two lines is not
possible.