![SIGMATEK HGT 1053 Operating Manual Download Page 65](http://html.mh-extra.com/html/sigmatek/hgt-1053/hgt-1053_operating-manual_1268124065.webp)
10.1" HANDHELD OPERATING PANEL
HGT 1053
20 Application Information
20.1 Configuring Safety Components
20.1.1 Minimum System Requirements
Component
Version
SAFETYDesigner
≥ 01.01.056 (Build: 2058)
SCP 111 firmware version
≥ 00.1049.448
INFORMATION
The actual time-out configured in the SCP 111 must be included in your
risk assessment!
20.1.2 Adding the HGT 1053 to a SAFETYDesigner Project
To use the HGT 1053 in a Safety project, it must be integrated as follows:
1. Create a new project or open an existing one.
2. Add an “SCP 111” to the “hardware tree” if not already available.
3. Right-click on
„0-SAFETY_INTERFACE“
, then via Add-Device, add the
„HBG
(HBG-CAN)“
.
20.1.3 Key Switch
In the SAFETYDesigner
Safe_Input5
and
Safe_Input6
are used fort he two-channel
application of the key switch.
20.1.4 Confirmation Switch
In the SAFETYDesigner
Safe_Input1
and
Safe_Input2
are used for the two-channel
application of the confirmation switch.
20.1.5 Emergency Stop
In the SAFETYDesigner
Safe_Input3
and
Safe_Input4
are used for the two-channel
application of the emergency stop switch.
24.03.2021
Page 63