HGT 1051
10.1“ HANDHELD CONTROL PANEL
Page 22
17.12.2019
X2:
M16 Cable Connector
The appropriate connector cables are optionally available.
See documentation for connection cables operating devices.
The handheld control panel can only be operated with the SCP XXX Safety
module!
As required by EN ISO 13850, section 4.1 and EN 60204-1, section 10.7.1, it
must be ensured that no confusion between a functioning and non-
functioning handheld control panel is possible.
Note on the Emergency Stop function: A non-connected HGT 1051 does not
have to be visibly sealed!
LED
Pin
Wire color
Function
L
Pink
Safety interface H
J
Gray
Safety interface L
G
shield
Safety interface shield
E
Red
+24 V DC
C
Black
GND
A
shield
ETH shield
And
Orange/white
E
th
e
rn
e
t1
E
th
e
rn
e
t2
T
Blue
ETH2_Rx-
S
Blue/white
R
Brown
ETH2_Tx-
P
Brown/white
O
Green
ETH1_Tx-
N
Green/white
M
Orange
ETH1_Rx-
LED Status
Definition
LED lights green
DC OK