To enter the mode for setting changes, press and hold the SET button while the C-IPC is
booting.
When the following appears in the display:
The SET button can be released.
After releasing the SET button, the first menu appears in the display.
With several short presses of the SET button, it is possible to scroll through the various
menu items. By pressing the SET button for approximately 1.5 s, the menu opens and the
settings can be made with a series of short presses.
Once the desired changes are made, press the SET button for about 5 seconds to end the
process. If the changes are to be discarded, press the RESET button to restart the C-IPC.
The settings for the IP address, subnet mask and gateway are hexadecimal, whereas in the
left and right digits, 0 - F must be entered separately. The switch occurs when the SET
button is pressed for about 1.5 s.
The values from AUTOEXEC.LSL are used as the standard settings; changes are written
back to this file. Before this, the original content of the file is written to AUTOEXEC.BAK.