background image

3

• Τhe siren installation and the wiring can be completed without applying power from the control  
  panel and remain so for a long time. It is activated by applying the supply voltage powered from  
  the control panel. This feature is particularly useful in cases of a building, where the siren is first  
  installed and the panel is powered after a long time. In this case, the siren’s consumption is 
  8 mA, the flash is not active to indicate standby mode and the siren will be switched on by the  
  first application of the supply voltage from the control panel.
• In standby mode, there are seven different - selected - modes of operation of the five Flash  
 LEDs.
• It has five different alarm sounds (selectable).
• It has two independent activation inputs, which operate with a positive or negative voltage 
 interruption.
• The siren follows the alarm duration of the control panel. However, the siren will also gives an  
  alarm, if the cables that connecting the siren to the panel, are cut-off or shorted.
 Specifically:
  -  gives a five (5) minutes alarm, if only the power supply cables are cut-off (+12 V) 
  -  gives a fifteen (15) minutes alarm, if only the TRIGGER cable is cut-off
  -  gives a five (5) minutes alarm, if both the power supply cables and TRIGGER cable are cut-off  
  simultaneously 
• It has short circuit protection on the battery charging (of the cables) output. 
• It has protection against faulty connection of the battery poles with simultaneous optical LED  
 indication.
• When the siren is in standby mode and its battery voltage drops bellow10.0 V, flash stops 
 flashing.
• It has a TAMRER to protect it from opening the outer cover and / or detachment from the wall  
  The Tamper switch has free contacts for easy connection to the control panel.
• Built-in FLASH, with five high brightness and low power LEDs with short-circuit protection.  
  These LEDs are flashing in various programmable modes when the siren is at standby mode.

General specifications 

Description

Self-powered and self-protective electronic siren with built-in FLASH, in two shades (red and 
blue), for easy detection of the area from which the alarm comes. It is an ideal combination of 
stylish design and quality construction and is manufactured under the strictest safety standards. 
The outer casing is made of high-strength polycarbonate, suitable for outdoor use. Inside it is pro-
tected by a metal cap made of galvanized sheet metal (in the Basic version) and it has protection 
against opening the outer lid or detaching the siren from the wall.

Summary of Contents for IRIS Lite

Page 1: ...1 Installation Manual IRIS Lite IRIS Basic Outdoor Self Powered Sirens ...

Page 2: ...2 ...

Page 3: ... cut off gives a five 5 minutes alarm if both the power supply cables and TRIGGER cable are cut off simultaneously It has short circuit protection on the battery charging of the cables output It has protection against faulty connection of the battery poles with simultaneous optical LED indication When the siren is in standby mode and its battery voltage drops bellow10 0 V flash stops flashing It h...

Page 4: ...d when the Trigger input has a 12VDC permanently It sounds an alarm if this voltage is inter rupted or when the voltage at this input is 5 8 V DC Activation from Trigger It is balanced when the Trigger input is permanently at 0 of the power supply and gives an alarm when the supply is cut off or when the input voltage is 1 5 V DC Operation Frequency 900 2700 Hz Acoustic Power 122dB at 1 meter Maxi...

Page 5: ... battery cable to 12V The siren can operate this way provided the cable s cross section allows it and the panel power supply is able to provide the required current Selecting the activation method of the siren The TRIGGER or inputs are used to activate the siren Activation can be done in two modes A By positive voltage interruption Connect the TRIGGER input of the siren to the corresponding output...

Page 6: ...ction terminals on page 5 and the following wiring diagram 6 When you finish cable connections connect the battery to the siren The siren can remain in this condition until you finish the installation The siren will start to operate normally only when supplied with power from the alarm control panel Note When the power supply is first applied from the panel to the siren a short sound will be heard...

Page 7: ... the one the siren will follow When all the LEDs are off the siren will have no lighting at standby mode Press MENU button to save settings Exit Setup To exit the programming procedure press continuously MENU button until the confirmation signal five BEEP is heard Immediately the siren will enter the standby mode The siren will also automatically exit programming and will return to standby mode af...

Page 8: ...The electrical and electronic equipment used must be handled separately and in accordance with the legislation which requires appropriate processing and recycling of the aforesaid goods The battery contains pollutants and therefore after the end of its lifetime it should not be disposed of in common waste but delivered to the appropriate operator for the collection and disposal of polluting waste ...

Reviews: