www.sigineer.com
42
34
Cell over voltage
Beep once every second
35
Cell under voltage
Beep once every second
36
Total over voltage
Beep once every second
37
Total under voltage
Beep once every second
38
Discharge over current
Beep once every second
39
Charge over current
Beep once every second
40
Discharge over temperature
Beep once every second
41
Charge over temperature
Beep once every second
42
Mosfet over temperature
Beep once every second
43
Battery over temperature
Beep once every second
44
Battery under temperature
Beep once every second
45
System shut down
Beep once every second
TroubleShooting
Problem
LCD/LED/Buzzer
Explanation
What to do
Unit shuts down
Automatically during
startup process.
LCD/LEDs and buzzer will
be active for 3 seconds
and then complete off.
The battery voltage is too low .
(<1.91V/Cell)
1.Re-charge battery.
2.Replace battery.
No response after
power on.
No indication.
1.The battery voltage is far too
low. (<1.4V/Cell)
2.Battery polarity is connected
reversed.
1.
Check if batteries and the wiring are connected well.
2.Re-charge battery.
3.Replace battery.
Mains exist but the
unit works in battery
mode.
Input voltage is 0 on the
LCD and green LED is
flashing.
Input protector is tripped.
Check if AC breaker is tripped and AC wiring is
connected well.
Green LED is flashing.
Insufficient quality of AC power.
(Shore or Generator)
1.
Check if AC wires are too thin and/or too long.
2.
Check if generator (if applied) is working well or if
input voltage range setting is correct.
(UPS→Appliance)
Green LED is flashing.
Set “Battery First” or “Solar First”
as the priority of output source.
Change output source priority to Utility first.
When it’s turned on,
internal relay is
switching on and off
repeatedly.
LCD display and LEDs are
flashing
Battery is disconnected.
Check if battery wires are connected well.
Buzzer beeps
Fault code 01
Fan fault.
1.Check whether all fans are working properly.
Summary of Contents for MS6048D
Page 6: ...www sigineer com 4...