background image

 

 

 

 

Off Grid Solar Inverter   

Remote LCD Panel(

Model #: MCRLCD

  User’s Manual 

 
 

 

 

For Solar Inverter Models: 

M3024NC 
M3048NC 

M3048BP 

M5000H-48BP 

M6048DUL 

M12048DUL 

etc 

 

Version 1.0 (PN:MCRLCD220509 

 

 

Manufacturer Information 

Sigineer Power Limited 

Email: [email protected] 

TEL: +86 769 82817616 

US Warehouse: 4415 S 32nd St, Phoenix, AZ 85040 

Summary of Contents for MCRLCD

Page 1: ...s Manual For Solar Inverter Models M3024NC M3048NC M3048BP M5000H 48BP M6048DUL M12048DUL etc Version 1 0 PN MCRLCD220509 Manufacturer Information Sigineer Power Limited Email info sigineer com TEL 8...

Page 2: ...ecting to Inverter 4 2 6 LCD Specification Setup 4 4 Maintenance Troubleshooting 16 5 Warranty 20 Please record the Sigineer Power unit s model and serial number in case you need to provide this infor...

Page 3: ...use this remote LCD panel on other equipments it is designed only to work with Sigineer Power solar inverters produced after 2022 May 2 Don t use any third party communication cables on the panel 3 D...

Page 4: ...ection Unit x1 User manual x 1 Communication cable 20m 65 6ft x 1 2 4 Installation There are two pieces of flanges which can be flexibly installed either on the panel top or two sides Surface Mounting...

Page 5: ...3 Flush Mounting with Flange on the Sides...

Page 6: ...el area includes three LED indicators four function keys and a LCD display It shows very rich operating info 1 LCD display 2 Status indicator 3 Charging indicator 4 Fault indicator 5 Function buttons...

Page 7: ...ppened Indicate short circuit happened Battery Information Indicate battery level by 0 24 25 49 50 74 and 75 100 in battery mode and charging status in line mode Indicate battery voltage battery perce...

Page 8: ...wer Indicates the utility charger circuit is working Indicates the DC AC inverter circuit is working These three signs indicate the output priority SOL FIRST indicates solar first BAT FIRST indicates...

Page 9: ...Utility Battery In this mode the inverter will transfer between DC and AC as per the settings of program 12 and 13 Users can set it to utility priority to stop the cycling 01 SbU SBU Priority As indi...

Page 10: ...P 95 140Vac 7V M5000H 48BP 170 280VAC 7V M6048DUL M12048DUL 184 272Vac 7V 03 GEN In Generator Mode the acceptable AC input voltage range M3024NC M3048NC M3048BP 65 140Vac 7V M5000H 48BP 90 280VAC 7V M...

Page 11: ...only when the battery voltage changes big enough Due to the ripple current from the utility charger when US2 is set for charging lithium batteries it is recommended to set the max utility charging cur...

Page 12: ...nt is set according to Program 02 for utility charger Program 12 DC to AC Transfer Voltage The setting works when program 01 is in SBU Priority or Solar Priority Mode Model Default Value Resettable Ra...

Page 13: ...the charger Program 20 Float Charging Voltage Model Default Value Resettable Range 48V Models 54V 48V 58 4V If user defined setting USE US2 is selected in program 5 this program can be set up Program...

Page 14: ...Charging Current Max PV Utility Charging Current 03 AC Input Voltage Range Appliance Mode Default 03 AC Input Voltage Range UPS Mode 03 AC Input Voltage Range Generator mode 04 Power Saving Mode Savi...

Page 15: ...rity Solar Priority 14 Charger Power Source Priority Solar and Utility Default 14 Charger Power Source Priority Solar Only 15 Alarm On Off Control Audible Alarm on default 15 Alarm On Off Control Audi...

Page 16: ...oltage Load percentage PV input voltage Battery voltage Warning or Fault code Default Display Screen AC Input frequency Output frequency Load power in VA PV energy sum in KWH Battery percentage Warnin...

Page 17: ...erter can charge battery without AC output Power saving mode If enabled the output of inverter will be off when connected load is two low or not detected No output is supplied by the unit but it still...

Page 18: ...rger switch to DC to AC model The M5000H 48BP inverters can be stacked up to 6 pcs to expand output power in 230Vac or create 230 400Vac three phase The M3048BP can be stacked up to 6 pcs to expand ou...

Page 19: ...9 Bus soft start failed 51 Over current or surge 52 Bus voltage is too low 53 Inverter soft start failed 55 Over DC voltage in AC output 56 Battery connection is open 57 Current sensor failed 58 Outpu...

Page 20: ...Beep once every second 16 Parallel input phase error Beep once every second 17 Parallel output phase loss Beep once every second 18 Buck over current Beep once every second 19 Battery disconnect No b...

Page 21: ...es are too thin and or too long 2 Check if generator if applied is working well or if input voltage range setting is correct UPS Appliance Green LED is flashing Set Battery First or Solar First as the...

Page 22: ...ery is not connected well or fuse is burnt If the battery is connected well please return to repair center Fault code 60 Negative power fault 1 Check whether the AC output connected to the grid input...

Page 23: ...lly or externally or damaged from improper use or use in an unsuitable environment violations of the warnings in the manual will invalid the warranty b the product if it has been subjected to fire wat...