For wall assembly the C22 Vibration Monitor should be mounted 
on its backside. For ground assembly the C22 Vibration Monitor 
should be mounted on its bottom side. 

3.

 

Close  the  flame  proof  enclosure  with  all  M8x30  bolts  and 
remember to renew the grease for a totally sealed box. 

4.

 

Mount  the  unit  in  the  desired  position.  As  stiff  mounting  as 
possible is recommended. 

For the system to work properly GSM connection is needed at the mounting 
location. Otherwise data will not be uploaded to the web service.  

 

 

Figure 1: The C22 position inside a ground mounted ATEX box 

Summary of Contents for INFRA C22 Ex

Page 1: ...Manual Copyright Sigicom AB 2020 Art no ML089 01870 0En INFRA C22 C20 Ex Wireless Triaxial Vibration System for explosive atmosphere Ex box art no 080 01870 0 ...

Page 2: ...Copyright Sigicom AB 2020 2 ...

Page 3: ... instrument make sure there are no restrictions of the use of radio transmitters at the intended site The unit is heavy take care and precautions when handling the unit Do not open the flame proof enclosure in an explosive environment always move the unit to a secure area before opening Carefully make sure that the flame proof enclosure is fully sealed with all screws and newly applied grease when...

Page 4: ...Copyright Sigicom AB 2020 4 Table of Contents 1 Introduction 5 1 1 Unpacking and Parts Identification 5 2 Mounting guide 5 3 Contact and support 8 ...

Page 5: ...re needs to be taken due to its high total mass Un sufficient mounting will result in erroneous results Suitable surfaces are concrete hard brick or similar The unit must not be attached to resilient structures such as corrugated steel sheet wall covering or weak beams The recommended procedure is Find or prepare a stiff and flat spot for the mounting either horizontal or vertical Concrete foundat...

Page 6: ...Close the flame proof enclosure with all M8x30 bolts and remember to renew the grease for a totally sealed box 4 Mount the unit in the desired position As stiff mounting as possible is recommended For the system to work properly GSM connection is needed at the mounting location Otherwise data will not be uploaded to the web service Figure 1 The C22 position inside a ground mounted ATEX box ...

Page 7: ...Copyright Sigicom AB 2020 7 Figure 2 The C22 position inside a wall mounted ATEX box ...

Page 8: ... support a part of our mission to provide the best functionality and viability of the measurement systems we deliver Every support request we receive is registered in our case management system and stay active until the case is resolved 46 8 44 99 770 support sigicom com www sigicom com ...

Reviews: