ICD-4000-OEM
© SightLine Applications, Inc.
4
4.2.2
Gap Pads Without SOM Cover
The cover may be removed if a machined heatsink interface is implemented.
STEP files for the OEM
with the SOM cover/heat spreader removed are available from SightLine that can help with heatsink
design and integration.
5
Connector Descriptions
Figure 3: 4000-OEM Connector Descriptions
Table 1: Connector Descriptions
Connector
Description
Mates with:
J2: Serial Port / GPIO
Serial port 1, GPIO
Molex 5POS Housing, 51021-0500
J4: Ethernet 10/100
Ethernet 10/100Mbps
Molex 4POS Housing, 51021-0400
J6: 3000/4000 Video Adapter Input
Digital video in 0, serial port 2, I
2
C-1, GPIO
DF12(3.0)-80DS-0.5V(86)
J7: 4000-DEBUG / Recovery
*
System recovery and debug serial port
Molex 8 POS Housing, 51021-0800
J8: USB 3.0 (Type-C)
USB 3.0 (type C)
USB Type-C Cable
J9:
MIPI Port (FFC connector)
MIPI Port, I
2
C-3 (Digital Video in 1, serial ports,
w/adapter board)
Sightline Cable SLA-CAB-MIPI-02
J15: MicroSD
MicroSD card slot
NA
J16: HDMI Output Video (FFC
connector)
HDMI Output (FFC)
Sightline Cable SLA-CAB-HD10
J25:
Additional Serial / GPIO
Serial port 0 and 3, GPIO
Molex 8POS Housing, 51021-0800
J50:
Power Connector
Typical 12VDC (see
min/max)
Molex 4POS Housing, 51021-0400
S2: IO2 SOM
INFORCE SOM. Pinout not included in this ICD.
For customers making custom interface boards,
contact
NA
S3: IO1 SOM
NA
*
The debug serial port is exposed on J7 P7-8 and should be reserved for debugging only. Debug serial port is 1.8V TTL
.
CAUTION:
J4 (Ethernet) and J50 (power) are adjacent 4-pin connectors.
DO NOT
connect power to the Ethernet
port. Connecting power to the Ethernet port
will
damage the board.