11
VIN0 has camera channels 0 and 1 assigned. VIN1 has camera channels 2 and 3 assigned. If the
configuration includes an analog board with a digital adapter board the analog board must be
installed on VIN0.
•
(optional smaller IO board): Provides serial and network interfaces. This board
allows SLA-3000-FPC board to be connected directly to the OEM board.
Cable connections:
•
SLA-CAB-FPC04: Connects to the SLA-3000-FPC board and to the Tau camera. Provides serial
communication and digital video to the camera. See
•
SLA-CAB-0403: Connects to J4 on SLA-3000-mIO board. Provides an RJ45 Ethernet connection.
•
SLA-PWR-C12V: Connects to J5 on SLA-3000-IO board.
•
SLA-CAB-1504 / SLA-PWR-B12V: Connects to J9 on the SLA-3000-mIO board.
The SLA-PWR adapters are rated at 110-250VAC input and 12VDC
output
.
Power and network connectivity LEDs:
•
A green light on the 3000-IO or 3000-mIO board indicates that all boards are powered on. An
amber light on the 3000-OEM board verifies network connection.
Figure 11: 3000-OEM - Neutrino Camera Bench Setup
SLA-3000-IO +
3000-OEM
Boards (stacked)
with MicroSD
Card
Network Switch or PC Direct
SLA-PWR-C12V
RJ45 Ethernet
SLA-3000-FPC
on VIN1
SLA-CAB-FPC04
Network Switch
or PC Direct
SLA-CAB-0403 (J4)
SLA-3000-OEM +
SLA-3000-mIO+
SLA-3000-FPC
SLA-3000-FPC
on J4
SLA-3000-mIO
on J1
SLA-CAB-FPC04
SLA-PWR-B12V
RJ45 Ethernet
SLA-CAB-1504 (J9)
All boards are immediately
powered on when power is
connected.
Cooler
Power
SLA-FPC-TAU
FLIR Neutrino
Direct
connect to
camera.