background image

Parameter

Description

Possible values

Default value

Length 
(in bits)

HIGH_ALARM_SETPOINT

High alarm setpoint for 
calculated value

32-bit float

1000000000

32

LOW_ALARM_SETPOINT_FACTOR

Low alarm setpoint for 
calculated value

8-bit unsigned integer
LOW_ALARM_SETPOINT =
HIGH_ALARM_SETPOINT * 
LOW_ALARM_SETPOINT_FACTOR
/ 200

0

8

ALARM_ENABLE

Enable/Disable ALARM
event

0b0 = ALARM event is OFF
0b1 = ALARM event is ON

0b0 = ALARM event is OFF

1

ALARM_PERIOD

Period of time to send 
ALARM event

0b000 = every  10min
0b001 = every  30min
0b010 = every 1h
0b011 = every 2h
0b100 = every 3h
0b101 = every 6h
0b110 = every 12h
0b111 = every 24h

0b000 = every  10min

3

LED_BUZZER_ENABLE

Enable/Disable LEDs and 
Buzzersinteractions for
action 
not triggered by the reed
switch

 

0b1 = LEDs and Buzzers
are ON

1

HEARTBEAT_PERIOD

Period of time to send 
HEARTBEAT event

0b000 = every  1h
0b001 = every  6h
0b010 = every 12h
0b011 = every 24h (1 day)
0b100 = every 48h (2
days)
0b101 = every 72h (3
days)
0b110 = every 120h (5
days)
0b111 = every 240h (10
days)

0b011 = every 24h (1 day)

3

MEASURE_PERIOD

Period of time to measure
sensor

0b0000 = every 1s
0b0001 = every 2s
0b0010 = every 5s
0b0011 = every 10s
0b0100 = every 20s
0b0101 = every 30s
0b0110 = every 1min
0b0111 = every 2min
0b1000 = every 5min
0b1001 = every 10min
0b1010 = every 20min
0b1011 = every 30min
0b1100 = every 1h
0b1101 = every 2h
0b1110 = every 3h
0b1111 = every 6h

0b1001 = every 10min

4

TX_REPEAT

Sigfox TX repeat

0b0 = Send RF 1 time
0b1 = Send RF 3 time

0b1 = Send RF 3 time

1

CYCLIC_DATA_PERIOD

Period of time to send 
CYCLIC_DATA event

0b000 = every  10min
0b001 = every  30min
0b010 = every 1h
0b011 = every 2h
0b100 = every 3h
0b101 = every 6h
0b110 = every 12h
0b111 = every 24h

0b001 = every  30min

3

DEVICE_RESET

Once this parameter is set,
the device shall restart
once after having received
the Downlink.

0b1010 = 0xA = force
device reset
others = do nothing

0b0000 = do nothing

4

DOWNLINK_TYPE

Downlink type

4-bit unsigned integer
See Sigfox Downlink tab

0b0000

4

The following is the format of payload data will be sent to Sigfox server. Length is 6 bytes, it is future-proof for

expansion to 12 bytes.

5.6 Configuration Parameters

5.7 Payload Data

5.7.1 Payload Fields

Summary of Contents for WSSFCEX-PPS

Page 1: ...ANGE 0 10 BARG ACCURACY 0 5 PROCESS CONNECTION 1 2 NPT MALE 316SS TYPE AA BATTERY 1 5VDC RC1 RC6 RC7 ZONES WSSFCEX PPS G 1000 SIGFOX GAGE PROCESS PRESSURE SENSOR ATEX EXD APPROVAL ZONE 1 2 RANGE 0 100...

Page 2: ...WSSFCEX PPS 1 1 FEB 2022 Update information of WSSFCEX PPS G 1000 WSSFCEX PPS is the Sigfox Integrated Process Pressure Sensor with Exd approval for installation in Zone 1 Zone 2 or Safe Zone and it...

Page 3: ...dard working time up to 10 years depends on configuration 02 x Battery AA 3 6V is also available as optional ATEX Certificates IMQ 14 ATEX 005 X T V CY 18 ATEX 0206158 X and IECEx DEK 15 0048X Marking...

Page 4: ...nd the number of times of alarm did not pass the limit of number of alarms then it will send data to Base station immediately 2 When the sending time interval is reached it will send data to Base stat...

Page 5: ...of REED SWITCH Buzzer beep 1 time hold Magnet Key 5s Buzzer beep 2 times Blink PURPLE Beep 2 times See FW specs Back to previous state Whenever the data is sent to base station the LED will lit with...

Page 6: ...eRadio Configuration menu Then release to configure it Press to configure After pressing if theBlue LED blinks once it is Radio Configuration 1 After pressing if the Blue LED flashes twice it is Radio...

Page 7: ...y Frequency hopping The device broadcasts each message 3 times on 3 different frequencies Maximum On time 400 ms per channel No new emission before 20 s Listen Before Talk Devices must verify that the...

Page 8: ...Step 3 Click New Select a group Step 4 Fill in the required information...

Page 9: ...ext as shown below Check the box as shown below to register as a prototype Note Some of our products may not have end product certification in time to add the product to Backend Sigfox please follow t...

Page 10: ...tain time to finish the measurement Once reading the value it can be scaled to any engineering value by the following formula Y aX b Where X the raw value from sensor Y the calculated value will be se...

Page 11: ...ys 0b111 every 240h 10 days 0b011 every 24h 1 day 3 MEASURE_PERIOD Period of time to measure sensor 0b0000 every 1s 0b0001 every 2s 0b0010 every 5s 0b0011 every 10s 0b0100 every 20s 0b0101 every 30s 0...

Page 12: ...ARM Alarm 0b00 no alarm 0b01 low alarm 0b10 high alarm 0b11 not used 2 BATTERY_LEVEL Battery level 2 bit unsigned integer 0 3 2 RAW_VALUE Raw value of pressure sensor 12 bit 16 bit unsigned integer 16...

Page 13: ...SSURE 9 0 bits 4 1 3 2 2 4 16 32 Value 0b0100 4 yes zeros yes yes zeros yes yes ALARM led blink RED Payload EVENT_ID HW_ERROR reserved ALARM BATTERY_LEVEL reserved RAW_VALUE PRESSURE 9 0 bits 4 1 3 2...

Page 14: ...TYPE 5 Payload PRM_ADDRESS PRM_LENGTH PRM_VALUE reserved DOWNLINK_TYPE 8 0 bits 8 8 16 28 4 Value yes 0x02 2 yes zeros 0b0101 5 Payload PRM_ADDRESS PRM_LENGTH PRM_VALUE reserved DOWNLINK_TYPE 8 0 bits...

Page 15: ...ttps filerun daviteq com wl id qK0PGNbY1g1fuxTqbFW9SXtEvCw7bpc6 Step 2 Plug the configuration cable to computer viaUSB port and install the driver Step 3 Open the housing Serial port configuration on...

Page 16: ...Step 4 Plug the connector to the configuration port Red Tx Black Rx Yellow GND Step 5 Insert the battery Tx on cable will go withRx on sensor and vice versa...

Page 17: ...LE FOR SIGFOX WSSFCEX PPS csv Here is the table of Data will be read by Modbus tool Modbus Register DEC Modbus Register Hex Function Code Read Function Code Write No of Registers Description Range Def...

Page 18: ...1 2 4 4 uint16 Read Write RC zones selection 1 2 4 is RCZ1 RCZ2 RCZ4 277 115 3 16 1 TX_POWER 20 int16 Read Write RF Tx power 278 116 3 16 2 CONSTANT_A 1 float Read Write Constant a for scaling measure...

Page 19: ...communicate with Base station but the distance will be reduced significantly 7 Installation 7 1 Locate the good place for Radio signal ATTENTION DO NOT install the Sigfox sensor or its antenna inside...

Page 20: ...er sensor specification 2 Please make sure the operating temperature and pressure is suitable with the sensor Please refer sensor specification 3 Prepare the professional tools for installation The in...

Page 21: ...aterials and size must be sizing properly to suit the process conditions It is better to install the isolation valve next to sensor process connector Steps for battery installation Step 1 Turn the fro...

Page 22: ...AA battery please take note the polarity of battery Step 4 Turn the front cover of the sensor clockwise to close fully ATTENTION REVERSED POLARITY OF BATTERIES IN 10 SECONDS CAN DAMAGE THE SENSOR CIRC...

Page 23: ...ckages day Check on the base station whether the event message exceeds the number of RF packets 5 Node has sent RF but the LED does not blink LED malfunction LED welding is not good Check LED conditio...

Reviews: