background image

 

 

OWNER´S MANUAL 

INSTRUCTIONS- INSTALLATION-OPERATION-MAINTENANCE 

OVENS AND MULTIPLES 

 

SR-4-24, SR-6-36, SR-24G -24, SR-36G -36, SR-4B-12G-36, SR-2B-24G-36 

 

**READ THIS MANUAL IN IT’S ENTIRELY BEFORE USING THIS RANGE** 

 

 

 

 

 

 

5659 ROYALMOUNT AVE MONTREAL, QC, CANADA H4P 2P9 
                      TEL (514) 737-9701; 1-888-275-4538 
 

Summary of Contents for SR-24G -24

Page 1: ...OPERATION MAINTENANCE OVENS AND MULTIPLES SR 4 24 SR 6 36 SR 24G 24 SR 36G 36 SR 4B 12G 36 SR 2B 24G 36 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS RANGE 5659 ROYALMOUNT AVE MONTREAL QC CANADA...

Page 2: ...NING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before install...

Page 3: ...cannot be adjusted If converting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is note...

Page 4: ...s Fuel ANSI Z21 41 or Quick Disconnect Devices for Use with Gas Fuel CANI 6 9 Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick di...

Page 5: ...valve and then to the pilot burner Gas flow is controlled by the safety valve Oven pilot lighting or relighting is to be completed in the following sequence 1 Turn the oven thermostat knob to off and...

Page 6: ...oven liner panels Wash all the above with hot soapy water then reassemble Baked on spills may be loosened and stubborn stains removed with ordinary household ammonia and scrubbing with a nylon pad in...

Page 7: ...s than under any circumstances All connections must be tested with a soapy water solution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attem...

Page 8: ...y piping system at test pressure equal to or less than psi 3 45kpa CLEARANCES The appliance area must be kept free and clear of all combustibles SR Series products are for installation in Non Combusti...

Page 9: ...rs operating gas pressure in inches WC and whether the appliance is orifices for natural or propane gas When communicating with factory about a unit or requesting for special parts or information Rati...

Page 10: ...INSTALLATION Identify the assemblies to be fitted over the equipment Make sure you have all the tools and fasteners listed Item Description Quantity PC 1 M6 SCREW FLAT 2 2 HEX SCREW 10mm 10 Flat screw...

Page 11: ...11 to 17 Remove the 3 rear screws of the unit Place the backsplash and make sure that the manifold fits in the hole on the right side support push...

Page 12: ...12 to 17 Place and tight the hex screws in the shown positions SHELF INSTALLATION Place the shelf over the backsplash and hook it on the very top of it Back Splash Shelf...

Page 13: ...13 to 17 Fit the M6 screws on the inside of the shelf to secure it in position REMOVE THE DOOR...

Page 14: ...in both hinges you can find 2 pieces of it in carton legs box STEP 2 Hold onto both hinges with your hands STEP 3 Raise the door until the door is at a 45 degrees angle STEP 4 Pull the door towards yo...

Page 15: ...LAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD...

Page 16: ...ierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any...

Page 17: ...514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canada H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United Stat...

Reviews: