Configuration Parameters
Timing Configuration
Parameter Name
Description
Addr
Default
Value
Type
Set Value
Get Value
dtmf_qual_delay
length of time dtmf tone must be detected by hardware to
be recognized
48
1
byte
C106 48 B (0…255) D C107 48 D
telemetrydelayl
time from key up to start of key up telemetry
49
8
byte
C106 49 B (0…255) D C107 49 D
xmittimeouts_long
time from key up to dropping carrier
50
40
byte
C106 50 B (0…255) D C107 50 D
xmittimeouts_short
time from key up to dropping carrier with link delay off
51
0
byte
C106 51 B (0…255) D C107 51 D
dtmftimeouts
timeout between dtmf entry to abort command entry
52
30
byte
C106 52 B (0…255) D C107 52 D
busytimeouts
dtmftimout for busy signal on case
53
60
byte
C106 53 B (0…255) D C107 53 D
id_idleto
time before ID is forced after transmit starts after long
transmit gap (repeater port)
54
30
word
C108 54 B (0…255) D C109 54 D
id_politeto
time remaining in absolute timeout when ID will be
triggered if transmit is idle (repeat port)
56
120
word
C108 56 B (0…255) D C109 56 D
id_absto
absolute timeout for sending ID (normally 10 minutes)
58
600
word
C108 58 B (0…255) D C109 58 D
id_lnkidleto
time before ID is forced after transmit starts after long
transmit gap (link port)
60
5
word
C108 60 B (0…255) D C109 60 D
cmdteldelays
delay after first command recognized until command
telemetry starts
62
15
byte
C106 62 B (0…255) D C107 62 D
serteldelays
delay after first command recognized until command
telemetry starts, with rs232 command source and
teltolocal=1. Value is 1 (defined by SERTELDELAYS0) if
teltolocal=0.
63
1
byte
C106 63 B (0…255) D C107 63 D
dialtonetimeout
timeout for dial tone after prefix recognized if not
command is entered
64
10
byte
C106 64 B (0…255) D C107 64 D
parmtimeout
timeout while waiting for a command parameter to be
entered
65
5
byte
C106 65 B (0…255) D C107 65 D
fantimeouts
timeout for fans after transmit stops
66
255
byte
C106 66 B (0…255) D C107 66 D
rcvqdelays_loc
time local receiver needs to detect COR and/or PL until
detected active, normal value
67
10
byte
C106 67 B (0…255) D C107 67 D
rcvunqdelays_loc
local receiver delay to drop receiver active, normal value
68
30
byte
C106 68 B (0…255) D C107 68 D
rcvqdelays_lnk
link receiver delay to receiver active detect, normal value
69
10
byte
C106 69 B (0…255) D C107 69 D
rcvunqdelays_lnk
link receiver delay to drop receiver active, normal value
70
1
byte
C106 70 B (0…255) D C107 70 D
rcvqdelays[]
specific radio values, set by set radio defaults
71
see above
byte
C106 71 B (0…255) D C107 71 D
rcvunqdelays[]
specific radio values, set by set radio defaults
79
see above
byte
C106 79 B (0…255) D C107 79 D
Strings
Parameter Name
Description
Addr
Default
Value
Type
Set Value
Get Value
allocated size of prefix
5
prefix_string
0 terminated string with prefix (0..9, A..B, # allowed)
87
special
allocated size of ID string
20
id_string
0 terminated string to be sent as repeater ID
92
special
id_string2
0 terminated string with alternate ID
112
special
allocated size of location string
20
loc_string
0 terminated string with location
132
special
loc_string2
0 terminated string with alternate location
152
special
idselect
OBSOLETE
172
0
byte
C106 172 B (0…255) D C107 172 D
Summary of Contents for Series 200
Page 1: ...Sierra Radio Systems Series 200 Control System Owners Manual Version 1 2 ...
Page 22: ...22 Radio I O II RIO II Board ...
Page 23: ...23 Configuring the Control System ...
Page 39: ...39 Installing New Firmware ...
Page 48: ...48 Control System Operation ...
Page 53: ...53 Control System Command Reference Guide ...
Page 105: ...105 Methodology for System wide Audio Level Setting ...
Page 109: ...109 ...
Page 110: ...110 ...
Page 111: ...111 Appendix ...
Page 121: ...121 ...