background image

 

 

 

11 

 

$0012   

40019   

Energy total – high word   

 

 

 

$0013   

40020   

Energy total – exponent   

16 bits int.   

 

$0014   

40021   

Energy flow – low word   

32 bits real   

 

$0015   

40022   

Energy flow – high word   

 

 

 

$0016   

40023   

Up signal int – low word   

32 bits real   

0

99.9 

$0017   

40024   

Up signal int – high word   

 

 

$0018   

40025   

Down signal int – low word   

32 bits real   

0

99.9 

$0019   

40026   

Down signal int – high word   

 

 

$001A   

40027   

Quality   

16 bits int.   

0

99 

$001B   

40028   

Analog output – low word   

32 bits real   

Unit: mA 

$001C   

40029   

Analog output – high word   

 

 

$001D   

40030   

Error code – char 1,2   

String   

Refer to “Error 
Analysis” for 

detailed codes 
meanings. 

$001E   

40031   

Error code – char 3,4   

 

 

$001F   

40032   

Error code – char 5,6   

 

 

$003B   

40060   

Velocity unit – char 1,2   

String   

Currently supports 

m/s only 

$003C   

40061   

Velocity unit – char 3,4   

 

 

$003D   

40062   

Flow unit – char 1,2   

String   

Note 1 

$003E   

40063   

Flow unit – char 3,4   

 

 

 

$003F   

40064   

Total unit – char 1,2   

String 

 

$0040   

40065   

Reserved   

 

 

 

$0041   

40066   

Reserved 

 

 

 

$0042   

40067   

Reserved 

 

 

 

$0043   

40068   

ID code – low word   

32 bits int.   

 

$0044   

40069   

ID code – high word   

 

 

 

$0045   

40070   

Serial number – char 1,2   

String   

 

$0046   

40071   

Serial number – char 3,4   

 

 

 

$0047   

40072   

Serial number – char 5,6   

 

 

 

Summary of Contents for InnovaSonic 205i

Page 1: ...InnovaSonic 205i Modbus Instruction Manual Modbus Device Specification for InnovaSonic 205 Transit Time Ultrasonic Flow Meter Part Number IM205i Modbus Rev V2 January 2015 ...

Page 2: ...tandard mass flow meters for oxygen gas You are responsible for determining if this mass flow meter is appropriate for your oxygen application You are responsible for cleaning the mass flow meter to the degree required for your oxygen flow application COPYRIGHT SIERRA INSTRUMENTS 2014 No part of this publication may be copied or distributed transmitted transcribed stored in a retrieval system or t...

Page 3: ...rning Always remove main power before disassembling any part of the mass flow meter Caution Before making adjustments to the device verify the flow meter is not actively monitoring or reporting to any master control system Adjustments to the electronics will cause direct changes to flow control settings Caution All flow meter connections isolation valves and fittings for hot tapping must have the ...

Page 4: ...ing Sierra Customer Service Technical Assistance If you encounter a problem with your flow meter review the configuration information for each step of the installation operation andsetup procedures Verify that your settings and adjustments are consistent with factory recommendations Installation and troubleshooting information can be found in the InnovaSonic 205i Product Instruction Manual If the ...

Page 5: ... of Contents Chapter 1 Using Modbus with the InnovaSonic 205i 6 1 1 RS 232 RS 485 Pin Definitions 6 1 2 Connection of RS 232 or RS 485 7 1 3 Setting Up the 205i to Use Modbus RTU 7 1 4 Modbus RTU Protocol 8 ...

Page 6: ...an be used to power on off other equipment The analog input of the system can be used to input signals such as pressure and temperature These analog values can be read using the Modbus RTU protocol to be used by customer software RS 232 50 ft or RS 485 up to 4 000 ft can be directly used for data transmission link for a short distance Current loop radio transmission and modems can be used in mediu...

Page 7: ...sor appears use the and keys to make your selection Press when done This window is used to setup the Modbus serial port baud rates Your choices are 9600 19200 38400 56000 57600 or 115200 This setting must match the master and other slaves on your Modbus network The Parity is fixed at None Data length fixed to eight Stop bit fixed at 1 Default factory serial port parameters are 9600 8 None 1 PC L N...

Page 8: ...a frame format Slave Address Read Operation Function Code Number of Data Bytes Data Bytes Verify Code 1 byte 1 byte 1 byte N x2 byte 2 byte 0x01 0xF7 0x03 2xN N x2 CRC Verify N data register number 2 Modbus Protocol function code 0x06 usage The host sends a command to write a single register information frame format performance code 0x06 Slave Address Operation Function Code Register Address Regis...

Page 9: ...ttention to the data storage order of the above example Using C language to explain the data pointers can be used directly to input the required data in the corresponding variable address the low byte will be put at the beginning such as the above example 1 2345678 m s 3F 9E 06 51 data stored in order as 51 06 9E 3F For example it converts the address 1 0x01 to 2 0x02 under the RTU mode so to writ...

Page 10: ...er 16 bits int 16 bit signed integer This allow for a number between 65 535 and 65 534 String 8 bit ASCII characters 2 per 16 bit register PDU Address Register Read Write Type No Registers 0000 40001 Flow s low word 32 bits real 2 0001 40002 Flow s high word 0002 40003 Flow m low word 32 bits real 2 0003 40004 Flow m high word 0004 40005 Flow h low word 32 bits real 2 0005 40006 Flow h high word 0...

Page 11: ...1C 40029 Analog output high word 001D 40030 Error code char 1 2 String 3 Refer to Error Analysis for detailed codes meanings 001E 40031 Error code char 3 4 001F 40032 Error code char 5 6 003B 40060 Velocity unit char 1 2 String 2 Currently supports m s only 003C 40061 Velocity unit char 3 4 003D 40062 Flow unit char 1 2 String 2 Note 1 003E 40063 Flow unit char 3 4 003F 40064 Total unit char 1 2 S...

Page 12: ...ess Register Description Read Write Type No Registers 1003 44100 Flowmeter address 1 247 R W 16 bits int 1 1004 44101 Communication Baud Rate 1 4800 2 9600 3 19K2 4 38K4 5 57K6 R W 16 bits int 1 Notes 1 The following flow rate units are available 0 m3 Cubic Meter 1 l Liters 2 ga Gallons 3 ig Imperial Gallons 4 mg Million Gallons 5 cf Cubic Feet 6 ba US Barrels 7 ib Imperial Barrels ob Oil Barrels ...

Reviews: