CDMA and GSM / UMTS Mini Card Hardware Integration Guide
20
Proprietary and Confidential
2130114
In the event of a discrepancy in values between this guide and the Product Specification Document (PSD), the PSD takes precedence.
For
instructions
on
using
the
commands,
refer
to
AT
Command
Set
for
User
Equipment
(UE)
(Release
6)
(+CFUN=0
command),
CDMA
CnS
Reference
(Document
2130754)
(CNS_RADIO_POWER
[0x1075]
command),
or
MC87XX
Modem
CnS
Reference
(Document
2130602)
(Disable
Modem
command).
Voltage monitoring state machine
The
module
has
a
state
machine
to
monitor
the
VCC3.3
(3.0
V
‐
3.6
V)
supply
(
Figure 2-2: Voltage monitoring state machine
Table 2-1: Voltage trigger levels
Condition
Voltage (V)
MC57xx
MC8775/75V
MC8780/81
MC8785V
MC8790/90V
MC8791V/92V
VOLT_HI_CRIT
3.6
3.6
3.6
VOLT_HI_NORM
3.5
3.5
3.5
VOLT_LO_NORM
3.1
3.1
3.1
VOLT_LO_WARN
3.0
3.0
3.05
VOLT_LO_CRIT
2.9
2.9
3.00
Normal
Low Supply Voltage
Critical
(Low power mode)
Low Supply Voltage
Warning
High Supply Voltage
Critical
(Low power mode)
current_vcc > VOLT_LO_NORM
current_vcc < VOLT_LO_WARN
current_vcc > VOLT_LO_NORM
Host asserts
W_Disable#
Host asserts
W_Disable#
current_vcc
< VOLT_LO_CRIT
current_vcc > VOLT_HI_CRIT
current_vcc < VOLT_HI_NORM
Power off.
Handled by
Power State
state machine.