Hardware and Software Installation
Rev 1.0 Mar.10
37
Step 5- Start ACEmanager
ACEmanager is a free utility. Follow the steps below to connect to ACEmanager.
•
Ensure MP connectivity to access ACEmanager.
•
Go to: http://192.168.13.31:9191 the first time you connect to ACEmanager.
•
Enter username as User and password as 12345.
•
By default ethernet uses public mode and all other interfaces are in private
mode using different subnets to differentiate the connection types.
The default private for Ethernet is also in a different subnet from the other
connection types.
*can be changed via ACEmanager
Table 4-1: Factory Defaults
Interface
MP
Connected Device
Ethernet Private default
192.168.13.31*
192.168.15.100
USB/NET
192.168.14.31
192.168.14.100
DUN
192.168.15.31
192.168.15.100
WiFi*
192.168.17.31
192.168.17.100