Page 5
2. General Information
Performances
Values are as measured per test method, except for the recommended heating area, firebox vol
-
ume, maximum burn time and maximum heat output.
1
Maximum Burn Time will vary depending on design of home, climate, wood type and operation
2
Heat Output Range results are determined during specific emissions tests established by the EPA.
3
As measured per CSA B415.1-10 stack loss method. The Maximum Heat Output value is representative of
a morefrequent re-fueling cycle than specified
4
Higher Heating Value of the fuel is obtained per CSA B415.1-10 test method.
5
Lower Heating Value of the fuel is obtained per CSA B415.1-10 test method.
6
Optimum overall efficiency at a specific burn rate (LHV).
7
This appliance is officially tested and certified by an independent agency. Particulate Emissions rate is
obtained using EPA Test Method.
8
Carbon Monoxide Emissions rate results from Test Method CSA B415.1-10.
Model
Lynwood W76
Type
Solid Fuel Room Heater
Type of Combustion
Non-catalytic
Fuel Type
Dry Cordwood (20% moisture)
Main Material
Cast Iron
Firebox Isolation
Vermiculite
Flue Exit
6” (150 mm) Back and top connector
Recommended Heating Area (sq. ft..)
450 to 2000 ft
2
(42 to 185 m
2
)
Nominal Firebox Volume
1.55 ft
3
(0.044 m
3
)
Maximum burn Time
1
14 hours
Maximum Heat Output (dry cordwood)
2
57,700 BTU/h (16.91 kW)
Overall Heat Output Rate (min. to max.)
2 3
13,784 BTU/h to 57,684 BTU/h
(4.04 kW to 16.91 kW)
Average Overall Efficiency
3
71 % (HHV)
4
76 % (LHV)
5
Optimum efficiency
6
78 %
Average particulate emissions rate
7
1.81 g/h (EPA / CSA B415.1-10)
Average CO
8
120 g/h