Masonry Chimney
Ensure that a masonry chimney meets the minimum standards of the National Fire Protection As-
sociation (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose
mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is
installed and operated. When connecting the stove through a combustible wall to a masonry chim-
ney, special methods are needed. Refer to Combustible Wall Chimney Connector Pass-Throughs
on the following pages. When connecting the SIERRA FLAME Lynwood to an existing chimney:
Remove the existing damper and/or any portion of the smoke shelf necessary to accommodate a 6
inch chimney connector. Install fireproof insulation batts between the connector pipes and the exist
-
ing flue. Connector pipes must be installed to allow access for chimney cleaning. Large chimneys
may not generate sufficient draft. A 6 inch stainless steel chimney liner extending tot he top of the
chimney is recommended.
CODE
APPROVED
FIREPLACE
CHIMNEY CONNECTORS
(supplied by others
FIREPLACE DAMPER
REMOVED
FIREPROOF INSULATION BATTS
(supplied by others)