Troubleshooting
en
55
Fault
Cause and troubleshooting
Pumping noise.
Condensation pump active.
▶
Not a fault – normal operating noise.
Buzzing noise.
Compressor ventilation active.
▶
Not a fault – normal operating noise.
The drying time is too
long.
The base unit's filter is soiled.
▶
"Cleaning the filter system on the base unit",
The ambient temperature is greater than 30 °C.
▶
Ensure that the ambient temperature is lower than
30 °C.
The ambient temperature is lower than 15 °C.
▶
Ensure that the ambient temperature is above 15
°C.
Insufficient air circulation at the appliance's installation
location.
▶
Ventilate the appliance's installation location.
Insufficient condensation for the automatic self-clean-
ing when permanently drying small loads of laundry.
▶
Regularly dry a load weighing more than 3 kg of
damp laundry until the programme ends.
Insufficient condensation for the automatic self-clean-
ing when permanently using the crease-removal func-
tion.
▶
Regularly dry a load weighing more than 3 kg of
damp laundry until the programme ends.
The appliance's ventilation opening is blocked.
▶
Ensure that the ventilation opening of the appliance
is kept clear.
Heat exchanger is soiled.
▶
Running the basic appliance care programme on
the appliance.
→
"Running the basic appliance care programme
The base unit filter is damp.
1.
"Cleaning the filter system on the base unit",
2.
Dry the filter thoroughly after cleaning.
3.
"Closing the base unit", Page 48
4.
"Switching off the appliance", Page 29
5.
"Switching on the appliance", Page 28
.