Display
en
23
Display
Designation
Description
Water consumption
Water consumption for the selected programme.
¡
: Low water consumption
¡
: High water consumption
End signal
Basic setting
Button signal
Basic setting
Display brightness
Basic setting
Reminder to clean the
drum
Flashes: Drum is dirty. Run the limp. tambor pro-
gramme for cleaning and caring for the drum and the
outer tub.
Voltage control system Flashes: The automatic voltage control system detects
impermissible voltage drops. This will pause the pro-
gramme.
Note:
The programme will continue when the voltage
is permissible again.
Voltage control system Flashes: The programme has been paused because of
impermissible voltage drops. The voltage is permiss-
ible again and the programme will continue.
Note:
The programme duration is extended.
Foam detection system The appliance has detected too much foam.
Door
¡
Lights up: The door is locked and cannot be
opened.
¡
Flashes: The door is not closed properly.
¡
Off: The door is unlocked and can be opened.
Tap
¡
No water pressure.
¡
The water pressure is too low.
E:60 / -2B
1
Error
Error code, error display, signal.
1
Example