en
Cleaning and maintenance
32
The drain hose at the siphon
is blocked
1.
Switch off the appliance.
2.
Disconnect the mains plug.
3.
Loosen the hose clamp. Carefully
remove the drain hose; residual
water may leak out.
4.
Clean the drain hose and siphon
connecting piece.
5.
Reattach the drain hose and secure
the connection using the hose
clamp.
Filter in the water supply is
blocked
First, reduce the water pressure in the
supply hose:
1.
Turn off the tap.
2.
Select any program (except Spin/
Drain//Spin/Empty).
3.
Press the
‹
button. Allow the
program to run for approximately 40
seconds.
4.
Turn the program selector to off
position.
5.
Pull out the mains plug.
6.
Clean the filter on the tap:
Disconnect the hose from the tap.
Clean the filter with a small brush.
7.
For standard and Aqua-Secure
models, clean the filter on the rear of
the appliance:
Remove the hose from the rear of
the appliance.
Use pliers to remove the filter and
then clean it.
8.
Insert the filter, connect the hose and
check for leaks.