background image

Published by Siemens Industry, Inc.  2020

Siemens Industry, Inc. 
3617 

Parkway 

Ln. 

     

Peachtree Corners, GA 30092 

Phone: +1 (800) 333-7421  

 

 

 

 

 

[email protected] 

      

usa.siemens.com/versichargeultra 

     

Article No. SIDS-T40088-00-4AUS   

 

 

 

Engineering  Doc  No.  P3REC000100052 

 

 

   

                                                     

Printed in USA                                                                                                                            
All Rights Reserved 
© 2020, Siemens Industry, Inc.                                                                                   

The technical data presented in this document is based on an actual case or on 
as-designed parameters and, therefore, should not be relied upon for any specific 
application and does not constitute a performance guarantee for any projects. 
Actual results are dependent on variable conditions. Accordingly, Siemens does 
not make representations, warranties, or assurances as to the accuracy, currency 
or completeness of the content contained herein. If requested, we will provide 
specific technical data or specifications with respect to any customer’s particular 
applications. Our company is constantly involved in engineering and 
development. For that reason, we reserve the right to modify, at any time, the 
technology and product specifications contained herein.

Summary of Contents for VersiCharge Ultra 175

Page 1: ...usa siemens com versichargeultra Front Back Maintenance Manual VersiCharge Ultra 175 175 kW DC fast charger ...

Page 2: ...ant safety instructions 3 Block diagram 4 Maintenance intervals 5 User unit maintenance 6 User unit maintenance checks 7 Isolated power unit maintenance 9 Isolated power unit maintenance checks 10 Electrical safety checks 11 2 ...

Page 3: ...so provides galvanic isolation of the charging system from the AC grid interface through the isolation transformer as well as charge control and communication to back office services CRITICAL Except as expressly stated herein all maintenance must be performed by a Siemens certified service agent only In the absence of a certified service agent the actions recommended in this manual should not be a...

Page 4: ...Block diagram Simplified Detailed excluding LV board Customer LV Distribution Board Isolated Power Unit User Unit VersiCharge Ultra 175 Maintenance Manual 4 ...

Page 5: ...re tight and firm C Rear door fans filter x2 Check filter Check for airflow Clean replace as required 1 C R UPS battery Check battery controller for alerts alarms Check and replace batteries as required C R Notes 1 Filter cleaning replacement is environment dependent Perform more frequently in higher pollution environments 2 Used batteries must be disposed of in accordance with applicable national...

Page 6: ...en General exterior maintenance Regular cleaning is recommended to avoid accumulation of debris dust dirt on or around the unit Wipe surfaces with a soft cloth dampened with water or use an alcohol based cleaner for harder to remove marks Do not spray with high pressure cleaning hoses or use abrasive chemicals Snowfall areas Regularly remove snow build up if present in front of the radiator panels...

Page 7: ...notify the supplier 5 Cable Management system Pull on the cables to check the retraction system of the cables If blocked contact your supplier Coolant level and radiator fans check 1 Coolant level inspection 1 Check if the coolant is at the correct level Note The coolant should be above the level indicated by the arrows in the following image 2 If the coolant level is below the half way arrow mark...

Page 8: ...nd plugs 2 Check for cuts holes cracks sharp edges and exposed copper 3 If you observe any cuts holes cracks etc contact your supplier 4 Check the contact pins for signs of corrosion 5 If corrosion is present contact your supplier VersiCharge Ultra 175 Maintenance Manual 8 ...

Page 9: ...damage to the unit contact your supplier It is recommended to perform general maintenance at least once a year depending on the environment In harsh environments general maintenance should be performed more often General exterior maintenance Regular cleaning is recommended to avoid accumulation of debris dust dirt on or around the unit Wipe surfaces with a soft cloth dampened with water or use alc...

Page 10: ...ally as part of continuous maintenance Doors 1 Check hinges for ease of movement and spray with a suitable water free lubricant 2 Check the lock for ease of movement and spray with a suitable water free lubricant Seals 1 Check the seals for damage around the contact areas 2 If any damage replace the seal Metalwork enclosure 1 Check for signs of corrosion or damage such as scratches 2 For minor cor...

Page 11: ...elief structures 8 Retorque any screw terminals especially contactor 9 Inspect the retention of rectifier module screw terminals these cannot be retorqued 10 Check the resistance of 50 Ohm discharge resistor and 25 Ohm discharge resistor can be done with a DMM with the power off 11 Retorque and check IMD connections and terminals 12 Check AC contactors in the IPU are in the released open position ...

Page 12: ... not be relied upon for any specific application and does not constitute a performance guarantee for any projects Actual results are dependent on variable conditions Accordingly Siemens does not make representations warranties or assurances as to the accuracy currency or completeness of the content contained herein If requested we will provide specific technical data or specifications with respect...