TC65 Hardware Interface Description
Strictly confidential / Draft
s
TC65_HD_V00.521
Page 77 of 99
24.05.2005
5.4
Power Supply Ratings
Table 18: Power supply ratings
Parameter Description
Conditions
Min
Typ
Max
Unit
Supply voltage
Directly measured at reference point
TP BATT+ and TP GND, see chapter
3.2.2
Voltage must stay within the min/max
values, including voltage drop, ripple,
spikes.
3.2 3.8
4.5
V
Voltage drop during
transmit burst
Normal condition, power control level
for P
out max
400 mV
BATT+
Voltage ripple
Normal condition, power control level
for P
out max
@ f<200kHz
@ f>200kHz
50
2
mV
mV
I
VDDLP
RTC Backup
@ BATT+ = 0V
25
µA
OFF State
supply current
POWER DOWN mode
1)
50
100
µA
SLEEP mode
@ DRX = 9
TBD
mA
SLEEP mode
@ DRX = 5
TBD
mA
SLEEP mode
@ DRX = 2
TBD
mA
I
BATT+
Average standby
supply current
2)
IDLE mode
@ DRX = 2
TBD
mA
1)
Measured after module INIT (switch ON the module and following switch OFF);
applied voltage on BATT+ (w/o INIT) show increased POWER DOWN supply current.
2)
Additional conditions:
SLEEP measurements started 3 minutes after switch ON the module
Averaging times: SLEEP mode - 3 minutes; IDLE mode - 1.5 minutes
Communication tester settings: no neighbor cells, no cell reselection
USB interface disabled