![Siemens TC65 Hardware Interface Description Download Page 62](http://html.mh-extra.com/html/siemens/tc65/tc65_hardware-interface-description_375442062.webp)
TC65 Hardware Interface Description
Strictly confidential / Draft
s
TC65_HD_V00.521
Page 62 of 99
24.05.2005
3.14.2 Using the SYNC Pin to Control a Status LED
As an alternative to generating the synchronization signal, the SYNC pin can be configured
to drive a status LED that indicates different operating modes of the TC65 module. To take
advantage of this function the LED mode must be activated with the AT^SSYNC command
and the LED must be connected to the host application. The connected LED can be operated
in two different display modes (AT^SSYNC=1 or AT^SSYNC=2). For details please refer to
[1].
Especially in the development and test phase of an application, system integrators are
advised to use the LED mode of the SYNC pin in order to evaluate their product design and
identify the source of errors.
To operate the LED a buffer, e.g. a transistor or gate,
must be included in your application. A sample circuit
is shown in Figure 26. Power consumption in the LED
mode is the same as for the synchronization signal
mode. For details see Table 17, SYNC pin.
Figure 26: LED Circuit (Example)