Stage setpoint for night cooling
Specify here the stage for the ventilation plant when night cooling is active.
Main menu > Ventilation > Night cooling > Stage setpoint:
Factory setting
Stage 1
Setting
Off
Stage 1
Stage 2
Stage 3
Precooling time max
Night cooling is released only during the set maximum precooling time
(0..2880 min). When the setting is 0 min, night cooling is disabled.
Main menu > Ventilation > Night cooling > Precool time max:
Factory setting
0 min
Setting
Ventilation settings
Holiday mode time
If the central apartment unit is in holiday mode (as per the settings in menu
Holidays / Special days), ventilation is reduced.
Ventilation uses the current apartment operating mode from the holiday pro-
gram and selects the required ventilation stage based on it.
This ventilation stage is operated daily at the set time (00:00..24:00) for the
specified duration.
Use this operating line to select the time to start ventilation while on holidays.
To start ventilation in holiday mode, the stage selection (page 45) must
be set to Auto.
Main menu > Ventilation > Ventilation settings > Holiday mode time:
Factory setting
10:00
Setting
Holiday mode period
Ventilation in holiday mode runs every day for the period set here
(00.00..06.00 hh.mm).
Main menu > Ventilation > Ventilation settings > Holiday mode period:
Factory setting
00.30 hh.mm.
Setting