7.3 Maintenance
The displays require little maintenance. Only the illumination properties slowly
change due to aging of the LCD unit and the backlight. Therefore the display
settings must be checked at regular intervals by servicing personnel according to
the regulations, and corrected as necessary.
The serial luminance meter and the serial spot meter are possible as measuring
instruments. Both units can be directly connected to the display.
The adjustment can be carried out automatically using the SMfit ACT program,
version 3.0 or later.
The settings can also be carried out manually using the serial spot meter and the
VOSD program.
21" gray scale flat panel display SMD 21300
17
A5E00185696B-001