Private Communication Systems
Mobile Phones
6Software programming
The software of the SL10 handset is programmed directly from a PC using a bootadapter as
an interface beetween serial port of the PC and the mobile. Because the SL10 does not carry
an external connector (e.g. like S6) an additional
service adapter
is needed.
This service adapter replaces the battery of the phone and contacts three pads inside the
battery department of the telephone. Via this contacts and the bootadapter a serial
communication is established between the SL10 and the PC.
6.1Description of software booting
p
Connect COM-port of PC to the
bootadapter using the enclosed RS232
cable.
H
Afterwards plug in AC-Adapter: If
connected correctly the „Power“ lamp
will be active.
¸
Switch off the SL10 handset and
remove the battery. Insert the service
adapter instead of the battery, connect it
to the boot adapter and plug in the AC-
adapter of the service adapter.
°
Copy bootsoftware to the PC and follow the instructions in the file „readme.txt“.
Ordering number of
Bootadapter:
L24857-F1006-A30
The bootadapter comes complete with AC-Adapter,
RS-232 and handset connection cable.
Ordering number of
Service Adapter: L36880-N1601-A130
The service adapter is shipped incl. AC-Adapter
Service Manual SL10
V1.1
PN MP ST
R. Fleuren
Sm_sl10_lvl2_v11.doc
Page
21
of 23
05/98
RS-232
cable
Bootadapter
Connection Cable
AC-Adapter
Service
Adapter
AC-Adapter