Weighing
Functions
Name
Type
Length
Default
Range of Values / Meaning / Display
Module name
STRING[10]
12
SIWAREX
MS
Name of weighing module
MLFB (20 characters)
STRING[20]
22
7MH4930-
0AA01
MLFB order number
Edition 1 HW
WORD
2
1
HW version
Firmware version
STRING[4]
6
V1.0
FW version
CRC checksum of
package
WORD
2
- - - -
Depending on code
44
Table 5-3
Allocation of DS 9
The purpose of the information in data record 9 is to identify the module, the
hardware and the firmware.
5.5 DS 15 Tare Entry
DS 15 is used for external specification of the tare weight.
Procedures:
o
Enter
tare
weight
o
Send DS 15 to the scale
o
Activate the command “Accept tare entry (24)”
Name
Type
Length
Default
Range of Values / Meaning
Tare input value
INT
2
0
Tare input value (preset Tare pT)
2
Table 5-4
Allocation of DS 15
5.5.1
DS 15 – Tare Entry
DS 15 is used for external specification of the tare weight. Once specified with DS
15, the tare value is not yet activated. The transfer to SIWAREX MS tare memory
is then done using command “Accept tare entry” (see command code
). The
specified tare value is rounded to the numeral step set in the parameters. The
rounded tare value is output in DS 30.
If the tare weight is defined through the controller then the transfer is not done
through data record DS15, it is done through the variable range. See chapter
.
5.6 DS 26 Internal Process Values
DS 26 is used to store the current internal process values. These values can be
read, saved and written back to the SIWAREX MS. However, you may not change
the values. Procedures:
o
Read the values.
o
Send the values to SIWAREX MS as required (after replacing modules)
(Not
possible if the wire bridge in on terminal P-PR)
.
5-30 SIWAREX
MS
Summary of Contents for SIWAREX MS
Page 1: ...SIWAREX MS Device Manual Status 12 2005 ...