![Siemens SITRANS WW100 Operating Instructions Manual Download Page 17](http://html.mh-extra.com/html/siemens/sitrans-ww100/sitrans-ww100_operating-instructions-manual_374523017.webp)
5. Use or
arrows to set the value to 3.
6. Press and hold
for 3 seconds to save.
You now have access to all of the parameter sets for both the Control Unit and Drive Unit.
4.2.1.4
Parameters
Note
In order to access or modify the parameter settings, P0003 must be set to EXPERT MODE
(see P0003 - Expert mode (Page 16)).
P2000 - Maximum RPM
Sets the maximum motor RPM.
The factory default value of the Drive configuration RPM is 6000. At the factory, we have set this
to a maximum of 2500
as the weighfeeder should not exceed the corresponding belt speed of
approximately 50 ft/min or 0.254 meters/second.
The application for which this weighfeeder will be used has been engineered by a software tool
at Siemens. From the data provided, certain parameters are generated identifying the
Design Rate, Design Speed, and Design Load. You are interested in the Design Speed: this will
aid in setting the Maximum RPM – P2000.
Calculating P2000
Design Speed P14 refers to Parameter 14 of the Siemens integrator BW500. Please see the
Technical Report supplied with the weighfeeder.
Imperial:
P2000 = Design Speed (P14-BW500) * k Factor (47.28702)
Metric:
P2000 = Design Speed (P14-BW500) * k Factor (9308.468)
Here are a few examples with both metric and imperial application data.
Design Speed
k Factor
P2000
Design Speed
k Factor
P2000
ft/min.
imperial
CU310-2
m/sec.
metric
CU310-2
10
47.28702
472.870
0.05080
9308.458
472.870
22
47.28702
1040.31
0.11176
9308.458
1040.31
35
47.28702
1655.05
0.17780
9308.458
1655.05
50
47.28702
2364.351
0.25400
9308.458
2364.351
1. Set S120 display to drive number 02 (see Switching units (Page 16)).
2. Use or arrows to navigate to P2000. The value should read 2500 after the application
software has been loaded.
3. Press
to access and view the current setting.
Installing
4.2 Electrical installation for servo driven models
SITRANS WW100
Operating Instructions, 06/2018, A5E33560618-AC
17