SITRANS P220 (7MF1567)
A5E03304437-AA, 09/2017
15
Input
0 ... 25 bar g
≥
-1 /
≤
62.5 bar g
150 bar g
0 ... 40 bar g
≥
-1 /
≤
100 bar g
240 bar g
0 ... 60 bar g
≥
-1 /
≤
150 bar g
360 bar g
0 ... 100 bar g
≥
-1 /
≤
250 bar g
600 bar g
0 ... 160 bar g
≥
-1 /
≤
400 bar g
960 bar g
0 ... 250 bar g
≥
-1 /
≤
625 bar g
1500 bar g
0 ... 400 bar g
≥
-1 /
≤
1000 bar g
2400 bar g
0 ... 600 bar g
≥
-1 /
≤
1500 bar g
2500 bar g
0 ... 1000 bar g
≥
-1 /
≤
1500 bar g
2500 bar g
Measuring range for relative pressure
(only for US market)
Overload limit
Burst pressure
0 ... 30 psi g
≥
-5.8 /
≤
80 psi g
420 psi g
0 ... 60 psi g
≥
-11.5 /
≤
140 psi g
580 psi g
0 ... 100 psi g
≥
-14.5 /
≤
300 psi g
520 psi g
0 ... 150 psi g
≥
-14.5 /
≤
350 psi g
870 psi g
0 ... 200 psi g
≥
-14.5 /
≤
550 psi g
1390 psi g
0 ... 300 psi g
≥
-14.5 /
≤
800 psi g
2170 psi g
0 ... 500 psi g
≥
-14.5 /
≤
1400 psi g
3480 psi g
0 ... 750 psi g
≥
-14.5 /
≤
2000 psi g
5220 psi g
0 ... 1000 psi g
≥
-14.5 /
≤
2000 psi g
5220 psi g
0 ... 1500 psi g
≥
-14.5 /
≤
3500 psi g
8700 psi g
0 ... 2000 psi g
≥
-14.5 /
≤
5500 psi g
13920 psi g
0 ... 3000 psi g
≥
-14.5 /
≤
8000 psi g
21750 psi g
0 ... 5000 psi g
≥
-14.5 /
≤
14000 psi g
34800 psi g
0 ... 6000 psi g
≥
-14.5 /
≤
14000 psi g
34800 psi g
0 ... 8700 psi g
≥
-14.5 /
≤
21755 psi g
36250 psi g
0 ... 14500 psi g
≥
-14.5 /
≤
21755 psi g
36250 psi g
Output
Current signal
4 to 20 mA
•
Load
(U
B
- 10 V) / 0.02 A
•
Auxiliary power U
B
7 ... 33 V DC
(10 ... 30 V for Ex)
•
Current consumption I
B
≤
20 mA
Voltage signal
0 ... 10 VDC
•
Load
≥
10 k
Ω
•
Auxiliary power U
B
12 ... 33 VDC
•
Current consumption
< 7 mA at 10 k
Ω
Characteristic curve
Linear rising
Measuring accuracy
Error in measurement at 25 °C (77 °F), including conformity
error, hysteresis and repeatability
•
Typical: 0.25% of full-scale value
•
Maximum: 0.5% of full-scale value
Set-up time T99
< 0.1 s
Long-term drift
Summary of Contents for SITRANS P220