Description
Specification
Residual ripple within voltage range
≤ 3.6 V
ss
Current consumption of SITRANS I300 (DC 24 V)
≤ 210 mA
Power loss (1.5 W load)
3.3W @ DC 24 V in
Reverse polarity protection
Yes
Table 9-2
Power supply output
Description
Specification
Rated voltage (output)
15.6 V
Max. current (output)
459mA
Max. power (output)
1.5W
Table 9-3
Galvanic isolation (Test voltage according to EN 60079-11)
Description
Specification
EIA-485 to EIA-485-IS
AC 1500 V
Power supply to EIA-485-IS
AC 1500 V
9.4
Diagnostics
Table 9-4
Diagnostics
Description
Specification
Monitoring 24 V power supply
Green LED "PWR"
Bus monitoring
Yellow LED "RX/TX"
Technical data
9.4 Diagnostics
SITRANS I300 Isolating power supply with EIA-485 interface
38
Operating Instructions, 01/2019, A5E45099319-AA