SITRANS FS230
A5E38755607-AA, 02/2017
21
6
Technical data
6.1
Power
Table 6-1
Power supply
Description
Specification
Supply voltage
•
100 to 240 V AC +10/-10%, 47 to 63 Hz
•
20 to 27 V DC +10/-10%
Power consumption
15 VA/7.5 W
Fluctuation
•
Transient overvoltages up to the levels of overvoltage
category II
•
Temporary overvoltages occurring on mains supply only
Reverse polarity protection (y / n)
Y
Galvanic isolation
3000 V AC
6.2
HART interface
Table 6-2
HART communication
Description
Specification
HART revision
7.5
Supported Device Managers
SIMATIC PDM V8.2 SP1 or newer
Supported Device Description (EDD)
V1.00.00
6.3
Operating conditions
Table 6-3
Basic conditions
Description
Specification
Ambient temperature
(Humidity max. 90 %)
Operation:
Transmitter without display
Display
-40 to +60 °C (-40 to +140 °F)
-20 to +60 °C (-4 to +140 °F)
Ambient temperature
(Humidity max. 90 %)
Storage:
-40 to +70 °C (-40 to +158 °F)
Climate class
DIN 60721-3-4
Altitude
Up to 2000 m (6560 ft)
Relative humidity
95 %
Bump resistance
On request
Shock resistance
On request
Thermal shock
On request
Vibration resistance
On request
EMC performance
•
Emission
•
Immunity
•
EN 55011 / CISPR-11
•
EN/IEC 61326-1 (Industry)
NAMUR NE 21