Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
98
Hardware Installation Manual, 11/2015, A5E34981613-AC
C1 Status
/Alarms: Aeration
10025 1 Bit
Coil
Binary_In
0
UINT16
n/a
DI(Dig In)
6
1
C1 Status
/Alarms: Memory
10026 1 Bit
Coil
Binary_In
0
UINT16
n/a
DI(Dig In)
7
1
C1 Status
/Alarms: Makeup
10027 1 Bit
Coil
Binary_In
0
UINT16
n/a
DI(Dig In)
8
1
C1 Status
/Alarms: Interface
10028 1 Bit
Coil
Binary_In
0
UINT16
n/a
DI(Dig In)
9
1
C1 Status
/Alarms: Zeroma-
tic
10030 1 Bit
Coil
Binary_In
0
UINT16
n/a
DI(Dig In)
2
1
C1 Delta Time
30179 4
Real
Analog_In
13
Float
n/a
ADF(Float)
8
1
C1 Delta Time
Units
30629 8
String
String_In
28
UINT16
n/a
BD(Byte)
57 8
C2 Site ID
30505 8
String
String_In
32
UINT16
n/a
BD(Byte)
65 8
C2 Inst.Flow
Rate
30111 4
Real
Analog_In
14
Float
129 7-07h
ADF(Float)
9
1
C2 Avg Flow
Rate
30123 4
Real
Analog_In
15
Float
129 2-02h S ADF(Float)
10 1
C2 Flow Rate
Units
30521 8
String
String_In
36
UINT16 131 2-02h
BD(Byte)
73 8
C2 Raw Flow
30135 4
Real
Analog_In
16
Float
n/a
ADF(Float)
11 1
C2 Raw Flow
Units
30541 8
String
String_In
40
UINT16
n/a
BD(Byte)
81 8
C2 Total
30147 4
Real
Analog_In
17
Float
129 35-23h ADF(Float)
12 1
C2 Total Units
30561 8
String
String_In
44
UINT16 131 35-23h BD(Byte)
89 8
C2 Sonic Vel
30159 4
Real
Analog_In
18
Float
n/a
ADF(Float)
13 1
C2 Sonic Vel
Units
30581 8
String
String_In
48
UINT16
n/a
BD(Byte)
97 8
C2 Signal
Strength
30168 2
Integer Analog_In
19
Float
n/a
ADF(Float)
14 1
C2 Sig Strength
Units
30597 8
String
String_In
52
UINT16
n/a
BD(Byte)
105 8
C2 Aeration
30173 2
Integer Analog_In
20
Float
n/a
ADF(Float)
15 1
C2 Aeration Units 30613 8
String
String_In
56
UINT16
n/a
BD(Byte)
113 8
C2 Sta-
tus/Alarms:
Spacing
10041 1 Bit
Coil
Binary_In
1
UINT16
n/a
DI(Dig In)
10 1
C2 Status
/Alarms: Empty
10042 1 Bit
Coil
Binary_In
1
UINT16
n/a
DI(Dig In)
12 1
C2 Status
/Alarms: Rate
10043 1 Bit
Coil
Binary_In
1
UINT16
n/a
DI(Dig In)
13 1
C2 Status
/Alarms: Fault
10044 1 Bit
Coil
Binary_In
1
UINT16
n/a
DI(Dig In)
14 1
C2 Status
/Alarms: Aeration
10045 1 Bit
Coil
Binary_In
1
UINT16
n/a
DI(Dig In)
15 1
C2 Status
/Alarms: Memory
10046 1 Bit
Coil
Binary_In
1
UINT16
n/a
DI(Dig In)
16 1