Safety, approvals, EMC
7.3 Approvals
SITOP PSU8200 1ph
Manual, 11.2014, C98130-A7633-A1-3-7629
51
Table 7- 2
Test voltage for 6EP1336-3BA10
Test time
Prim ↔ sec (A)
Prim ↔ PE (B)
Sec ↔ PE (C)
Type test
60 s
4200 VDC
2200 VDC
700 VDC
60 s
3000 VAC
1500 VAC
500 VAC
Production test
1 s
2200 VDC
2200 VDC
500 VDC
1 s
1500 VAC
1500 VAC
350 VAC
Field test
1 s
2200 VDC
2200 VDC
500 VDC
1 s
1500 VAC
1500 VAC
350 VAC
Remark:
Tripping current for DC measurement: 0 mA
Tripping current for AC measurement: <100 mA
7.3
Approvals
6EP3333-8SB00-0AY0 (24 V/5 A)
6EP3334-8SB00-0AY0 (24 V/10 A)
6EP1336-3BA10 (24 V/20 A)
CE marking
Yes, (2004/108/EG and 2006/95/EG)
Yes, (2004/108/EG and 2006/95/EG)
UL/cUL (CSA) approval
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259
cULus-Listed (UL 508, CSA C22.2
No. 107.1), File E197259
Explosion protection
EPS 12 ATEX 1 640 X
IECEx EPS 14.0057X
II 3G Ex nA nC IIC T4 Gc
cCSAus HazLoc Class I, Div 2, Group
A,B,C,D T4
EPS 12 ATEX 1 442 X
IECEx EPS 14.0062X
II 3G Ex nA nC IIC T3 Gc
cCSAus HazLoc Class I, Div 2, Group
A,B,C,D T3
CB approval
Yes, (IEC 60950-1)
No
SEMI F47 compliance
Fulfilled
-
Marine approvals
GL, ABS
GL, ABS